Enecsys Double Repeater User Manual

Double repeater

Advertisement

Quick Links

intelligent reliable power
E n e c s y s M i c r o - I n v e r t e r s
D o u b l e R e p e a t e r U s e r M a n u a l
Version 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Double Repeater and is the answer not in the manual?

Questions and answers

Summary of Contents for Enecsys Double Repeater

  • Page 1 intelligent reliable power E n e c s y s M i c r o - I n v e r t e r s D o u b l e R e p e a t e r U s e r M a n u a l Version 1.0...
  • Page 2: Table Of Contents

    When to install an Enecsys Double Repeater Installation Attaching the internal antenna Mounting the Enecsys Double Repeater Wall mounting the Enecsys Double Repeater (adhesive pad method) Wall mounting the Enecsys Double Repeater (screw fixed method) Mounting with a cable tie Installing the external antenna...
  • Page 3: Introduction

    Although the installation is simple a basic knowledge of internet routers, wired or wireless may be beneficial although not necessary. Installation of the Enecsys Double Repeater is a 'plug and play'. Enecsys have designed the hardware to be a simple as possible for the installer and end- user alike.
  • Page 4: Conventions Used In This Manual

    Caution statements should be followed at all times. Attention: Attention statements are used to indicate where a part of the process or instrument has a special requirement. Attention statements should be followed at all times. © ENECSYS 2010. All rights reserved.
  • Page 5: Safety

    Intelligent Reliable Power 1.2 Safety Before installing and using the any Enecsys Repeater please ensure that you have fully read and understand all of the installation and user instructions and heed all warnings and cautions given. Install in a clean dry environment, indoors and if possible away from heat sources and out of direct sunlight.
  • Page 6: Scope Of Delivery

    1.3 Scope of delivery The following list details the scope of delivery, please ensure that all parts are present before starting the installation. 1 x Enecsys Double Repeater. 1 x Fixed antenna. 1 x External antenna. 1 x Coaxial cable reverse polarity with RP SMA connectors, 15 - 30 meter lengths.
  • Page 7: Enecsys Double Repeater

    Enecsys Double Repeater in order to provide stable communications between the inverters and the Gateway over a long time period. An Enecsys Double Repeater is used in situations where a Single Repeater is unable to provide the Gateway with a strong sustainable communication link.
  • Page 8: Installation

    Enecsys Double Repeaters are employed to improve the communication link between the inverters and the Gateway. The Enecsys Double Repeater is a 'plug and play' device; it is quickly and easily installed. The Enecsys Double Repeater should be installed within the roof-space of the building and positioned within easy connection distance of a mains supply AC power source.
  • Page 9: Attaching The Internal Antenna

    2.1 Attaching the internal antenna Attach the antenna to the RP SMA connector on the right hand side of the Enecsys Gateway. 1. Attach the antenna to the lower SMA plug on the right hand side of the Repeater, screw the antenna into place in a clockwise direction.
  • Page 10: Mounting The Enecsys Double Repeater

    Intelligent Reliable Power 2.2 Mounting the Enecsys Double Repeater The Enecsys Double Repeater can be either free standing or wall mounted. In each case the Enecsys Double Repeater should be installed in a location where it is unlikely to be moved, indoors, away from heat sources and out of direct sunlight.
  • Page 11: Wall Mounting The Enecsys Double Repeater (Adhesive Pad Method)

    3. Connect the supplied external 5V DC power jack-plug to the DC power port on the reverse of the Enecsys Double Repeater, thread the cable through the semi-circular channel on the back- plate of the Enecsys Double Repeater, this will help to keep the cable in place and prevent it from becoming detached.
  • Page 12: Wall Mounting The Enecsys Double Repeater (Screw Fixed Method)

    5. Mark two horizontal spots on the wall 50 millimetres apart, install the screws into the wall. 6. Line up the back plate holes of the Enecsys Double Repeater with the screws on the wall and then slide the Enecsys Double Repeater down to fix the unit in position.
  • Page 13: Mounting With A Cable Tie

    There may be situations where it is not possible to mount the Enecsys Double Repeater using the screw fixed or adhesive pad method. A cable tie can be utilised to fix the Enecsys Double Repeater to an internal pillar or suitable structure.
  • Page 14: Installing The External Antenna

    Always ensure that the cable isn't arranged such that water or condensate can run down coaxial cable and onto the repeater. 1. Ensure that you have enough coaxial cable to reach from the mounting point to the Enecsys Double Repeater.
  • Page 15: Turning The Enecsys Double Repeater On

    To turn the Enecsys Double Repeater on feed the power cable through the power cable conduit, attach the 5V DC power supply jack-plug from the power port on the reverse of the Repeater.
  • Page 16: Turning The Enecsys Double Repeater Off

    Intelligent Reliable Power 2.8 Turning the Enecsys Double Repeater off The Enecsys Double Repeater comes supplied with a 5V DC external power supply. The power adaptor serves as the disconnect device - a socket outlet in accordance to the national wiring codes for the country shall be installed near the equipment and shall be easily accessible.
  • Page 17: Technical Specification

    Output; 5V DC, 1.2A. with 2.1mm jack. Table 1: Power adapter. Operating Temperature Temperature range 10°C to +40°C. Table 2: Operating temperature. Interface Specifications Ethernet Interface RJ45, 10Base-T or 100Base-TX. Table 3: Interface specification. © ENECSYS 2010. All rights reserved.
  • Page 18 12 months warranty. Table 4: Life expectancy. Fixed Internal Antenna Radiating element 1/2 Wave Element. Frequency range 2.4 GHz. Peak gain 2.0 dBi. Polarisation Linear. Connector SMA Male. Dimensions 139 x 13mm. Table 5: Fixed antenna. © ENECSYS 2010. All rights reserved.
  • Page 19 -13 dB Return loss SMA Male Connector 139 x 13mm Dimensions Table 6: External Antenna. *External Antenna - For adetailed technical description of installation of the external antenna please refer to external antenna installation guide. © ENECSYS 2010. All rights reserved.
  • Page 20: Compliance

    (2) this device must accept any interference, including interference that may cause undesired operation of the device. Changes or modifications made to this device that are not expressly approved by Enecsys Ltd may void the user's authority to operate the equipment.
  • Page 21: Printing

    3.2 of the R&TTE Directive. 5. Printing Please print this manual once and then keep it in a safe place for future reference. If you intend to dispose of this manual please recycle. © ENECSYS 2010. All rights reserved.