KNX AQS-UP basic Installation And Adjustment Manual

Air quality sensor

Advertisement

Quick Links

EN
KNX AQS-UP basic
Air Quality Sensor
Article numbers 70224 (white), 70225 (aluminium), 70226 (anthracite), 70227 (stainless steel)
Installation and Adjustment

Advertisement

Table of Contents
loading

Summary of Contents for KNX AQS-UP basic

  • Page 1 KNX AQS-UP basic Air Quality Sensor Article numbers 70224 (white), 70225 (aluminium), 70226 (anthracite), 70227 (stainless steel) Installation and Adjustment...
  • Page 2: Table Of Contents

    4.7.3. Connection inputs of the OR logic ............. 23 Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany Sensor KNX AQS-UP basic • from software version 3.1, ETS programme version 3.1 Status: 24.03.2016 • Subject to technical changes. Errors excepted.
  • Page 3 Clarification of signs Installation, inspection, commissioning and troubleshooting of the device must only be carried out by a competent electrician. This manual is amended periodically and will be brought into line with new software releases. The change status (software version and date) can be found in the contents footer. If you have a device with a later software version, please check www.elsner-elektronik.de in the menu area "Service"...
  • Page 4: Description

    • Socket Ø 60 mm, 42 mm deep • Frame (for element 55 x 55 mm), suitable for the switching programme used in the building Air Quality Sensor KNX AQS-UP basic • Version: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 5: Technical Specifications

    (without interruption of the bus voltage) as a reference for fresh air. Air Quality Sensor KNX AQS-UP basic • Version: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 6: Installation And Commissioning

    (standing or sitting, according to utilization of room). The CO concen- tration in indoor rooms is highest near the floor and decreases towards the ceiling. Air Quality Sensor KNX AQS-UP basic • Version: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 7: Composition

    2.3. Composition 2.3.1. Housing Fig. 1 Base plate Notches Air circulation holes Programming LED (recessed) Programming button (reces- sed) for teaching instrument Air circulation holes (BOTTOM) Air Quality Sensor KNX AQS-UP basic • Version: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 8: Rear View Of Sensor Board With Connections

    After the bus voltage has been applied, the device will enter an initialisation phase last- ing a few seconds. During this phase no information can be received or sent via the bus. Air Quality Sensor KNX AQS-UP basic • Version: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 9 Installation and commissioning Air Quality Sensor KNX AQS-UP basic • Version: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 10: Transfer Protocol

    C R W T value CO2 threshold value 2: (1:+ | 0:-) Input 1,002 CO2 threshold value 2: Switching Input 7,005 delay from 0 to 1 Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 11 (1=ON | 0=OFF) CO2 controller: Ventilation 2 status Output 1,001 C R T (1=ON | 0=OFF) Comparator 1 actuating variable: Input 5,010 Input 1 Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 12 AND logic 4: 8-bit output A Output 5,010 C R T AND logic 4: 8-bit output B Output 5,010 C R T AND logic 4: Block Input 1,002 Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 13 OR logic 6: 8-bit output A Output 5,010 C R T OR logic 6: 8-bit output B Output 5,010 C R T OR logic 6: Block Input 1,002 Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 14: Parameter Setting

    The device sends all outputs according to their send behaviour set in the parameters with the delays established in the "General settings" parameter block. The "Software version" communications object is sent once after 5 seconds. Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 15: General Settings

    Use maximum value Yes • No Note: The values are not retained after a reset. Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 16: Co2 Threshold Values

    • after restoration of power • after restoration of power and programming Start threshold value in ppm 0...5000; 1200 valid till 1st communication Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 17: Switching Output

    • Do not send message • send 0 • send 1 On release [Dependent on the "Switching output (with 2 seconds release delay) sends" setting] Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 18: Co2 Pi Control

    The status object shows the current status of the output variable (0 = OFF, >0 = ON) and can for example be used for visualisation. Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 19: Controller Target Value

    Absolute value • Increase/decrease Step size in ppm 1 • 2 • 5 • ... • 20 • ... • 100 • 200 (upon increase/decrease change) Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 20: Ventilation Control

    Determine what the control variable comparator should output, and activate the input objects to be used. Send behaviour and blocks can also be set. Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 21: Logic

    Logic input 1... 16 0 • 1 AND logic Logic 1/2/3/4/5/6/7/8 not active • active OR logic Logic 1/2/3/4/5/6/7/8 not active • active Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 22: And And/Or Or Logic 1/2/3/4/5/6/7/8

    • at value 1: block | at value 0: release • at value 0: block | at value 1: release Blocking object value before 1st communi- 0 • 1 cation Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 23: And Logic Connection Inputs

    Logic input 6 inverted Logic input 7 Logic input 7 inverted Logic input 8 Logic input 8 inverted Logic input 9 Logic input 9 inverted Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 24: Connection Inputs Of The Or Logic

    AND logic output 5 inverted AND logic output 6 AND logic output 6 inverted AND logic output 7 AND logic output 7 inverted AND logic output 8 Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 25 Parameter setting AND logic output 8 inverted Sensor KNX AQS-UP basic • from software 3.1 • Status: 24.03.2016 • Technical changes reserved. Errors reserved.
  • Page 26 Elsner Elektronik GmbH Control and Automation Technology Sohlengrund 16 75395 Ostelsheim Phone +49(0)70 33/ 30945-0 info@elsner-elektronik.de Germany +49 (0) 70 33/ 30945-20 www.elsner-elektronik.de Technical support: +49 (0) 70 33 / 30 945-250...