Wiring - Fujitsu UTB-*WB series Installation Manual

Vrf system ir receiver unit
Table of Contents

Advertisement

3
1
1
2
1 Install the cover.
Hook the 2 projections on the top of the cover onto
the bracket (cover), and then hook the projection on
the bottom of the cover onto the bracket (cover).
2 Make sure that there is no gap between the cover and
the wall or ceiling.
II. Attaching the receiver unit
1
Holder
2
(PCB)
Holder cover
Screw
1
1 Remove the screw.
2 Remove holder (PCB)
from holder cover.
3
Wall or
ceiling
2
1
2
Screws (M4 x 20mm)
1 Affix the insulation to
the holder cover.
2 Attach the holder cover
to the wall or ceiling with
the screws (included
with the standard parts).
III. Attaching the receiver unit to the indoor unit (EXAMPLE
AR07-18)
1
2
Screw
1
1 Remove the screw.
2 Remove holder (PCB)
from holder cover.
Cover
Bracket
(cover)
Cover
2
1 Cut the projections in
the areas indicated with
a
and remove them.
(Be careful not to injure
yourself on the cut edges
of the holder cover.)
4
1
Hook
2
1 Reattach holder cover.
(Make sure that the
hook on the holder cover
is caught on the holder
[PCB].)
2 Fix holder (PCB) by the
screw.
2
1 Cut the projections in
the areas indicated with
a
and remove them.
(Be careful not to injure
yourself on the cut
edges of the holder
cover.)
3
Screw
2
(M4 x 12mm)
1
1 Affix the insulation to the
holder cover.
2 Attach the hook metal to
the holder cover with
the screw (included with
the standard parts).

7. WIRING

WARNING
Before starting installation work, turn off the power of this
unit and the connection destination. Do not turn on the
power again until installation is completed. Otherwise, it
will cause electric shock or fire.
Use the accessories or specified power cable and
connection cables. Do not modify power cable and
connection cables other than those specified, do not use
extension cables, and do not use independent branch
wiring. The allowable current will be exceeded and cause
electric shock or fire.
Install the connection cables securely to the terminal
board. Confirm that external force is not applied to the
cable. Use connection cables made of the specified
cable. If intermediate connection or insertion fixing are
imperfect, it will cause electric shock, fire, etc.
When connecting the power cable and communication
cable, layout the wiring so that the cover of this unit is
securely fixed. If the cover is imperfectly fixed, it may
cause fire or overheating of the terminals.
Perform ground work positively. Do not connect the
ground cable to a telephone ground cable, water pipe, or
conductor rod.
Always fasten the outside covering of the connection
cable with the cable clamp. (If the insulator is chafed,
electric leakage may occur.)
When performing cable wiring work, be sure that it does
not touch the user. Doing so will cause injury or electric
shock.
If any cable is damaged, do not repair or modify it
yourself. Improper work will cause electric shock or fire.
4
Screws
(M4 x 10mm)
1
1
1 Attach the hook metal to
the indoor unit with the
screw(s).
En-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents