INSTALLATION

TYPE A
For installation directly to first-stage high pressure port
1.
Write down the serial number on the metal base of the Tank POD (for pairing).
2. Insert the Type A flow restrictor into the Tank POD.
3. Attach the Tank POD to the first-stage high pressure port.
4. Slowly and steadily open the pressure valve. Look away as your gear is
pressurized.
5. Wait for green LED on the Tank POD to flash.
6. If your Suunto EON device has a blank screen, press any button to activate it.
7.
Hold your device close to the Tank POD.
8. Select the gas for the Tank POD you have just pressurized based on the serial
number of the POD.
TYPE B
For installation to high pressure hose extension to first-stage high pressure port
1.
Write down the serial number on the metal base of the Tank POD (for pairing).
2. Insert the smooth end of Type B flow restrictor into the Tank POD. The grooved
end should remain visible.
3. Attach the high pressure hose extension to the first-stage high pressure port.
4. Attach the Tank POD to the end of the high pressure hose extension, ensuring the
grooved end of the restrictor is inserted into the hose.
5. Slowly and steadily open the pressure valve. Look away as your gear is
pressurized.
6. Wait for green LED on the Tank POD to flash.
7.
If your Suunto EON device has a blank screen, press any button to activate it.
8. Hold your device close to the Tank POD.
9. Select the gas for the Tank POD you have just pressurized based on the serial
number of the POD.
WARNING: The battery level indication shown when pairing the Tank POD is an
approximation only. The POD battery may deplete faster than the indication suggests.