DIP Switch CONFIGURATIONS (Optional)
REMOVING THE FRONT PANEL
- Dip switches are located behind the front panel,
through an opening below the control panel. T
access, remove front panel. See Fig. 2.
- Dip switches are accessible without opening the
control box. See Fig. 3.
- Unit must be OFF to effectively change
dip switch statuses.
DIP Switch CONFIGURATIONS
- See Table 1 and Fig. 4 for configurations
and functions of each dip switch position.
1 2 3 4
1 2 3 4
A0-
A3
Fig.4
No .
UP(ON)
Electric Heat Only
S1
Temperature Display in C
S2
Wall Thermostat Enable
S3
O
UP*UP:61 F~86 F(16 C~30 C);
S4*S5
UP*DOWN:65 F~78 F(18 C~26 C);
DOWN*UP:63 F~80 F(17 C~27 C);
DOWN*DOWN:68 F~75 F(20 C~24 C);
S6
Fan Continuous Run for Heating
S7
Fan Continuous Run for Cooling
S9
Use some type of wall
thermostat
NOTE: On heating mode, the setting temperature
cannot be higher than 29 C/84 F.
Electric Heat Only (for heat pump unit only)
- This setting is typically used for Emergency Heating.
Wall Thermostat Enable
- A wired wall thermostat can be connected to the
unit. If it is, the dip switch must be moved to the
Wall
Thermostat Enable Position before the wall
thermostat will begin control.
Set Point Temperature Limits
- Provide a restricted range of temperature control.
UP (ON)
1 2
1 2 3 4
DOWN (OFF)
A4 A5
Wall thermostat
Heating type
Temperature display type
Control type
Setpoint limit 1
Setpoint limit 2
Fan CON/CYC for heating
Fan CON/CYC for cooling
Table 1
DIP Switch CONFIGURATIONS
Electric Heat and Pump Heat
O
Temperature Display in F
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Use PTAC
thermostat
O
O
o
- Pull out at the bottom to release it from the tabs
- Then lift up
type
DOWN(OFF)
Control Panel Enable
O
Fan Cycle for Heating
Fan Cycle for Cooling
or other wall
Heat and Cool Fan CON/CYC Dip Switches
- Allow the fan to operate in continuous or cycle
modes while the unit is in heating and cooling mode.
CON (Continuous)
- Allows fan to continuously circulate air even when the
temperature setting has been satisfied. This switch helps to
maintain the room temperature closer to the thermostat
setting.
CYC (Cycle)
- This setting allows the fan to cycle on and off with the
compressor or electric heater
after the temperature setting is satisfied.
8
2
1
.
2
Fig.2
Dip Switches
Fig.3
Remarks
For Heat Pump Unit Only
O
Two configurations (S4*S5)
combine to select set point
range.
Consult with the sales agency
or manufacturer for details
. The fan stops a short time
.