Fujitsu ARA12LATN Service Instruction page 48

Duct type inverter indoor / outdoor units
Table of Contents

Advertisement

2-2. For AR*A36/ 45LATN
(Table 13-2 : Current Release Operation Value / Release Value)
[ Heating ]
T0 >
20°C
=
20°C >
T0 >
12°C
=
T0 <
12°C
T0: Outdoor temperature
[ Cooling ]
T0 >
46°C
=
46°C >
T0 >
40°C
=
40°C >
T0 >
31°C
=
31°C >
T0 >
25°C
=
25°C >
T0 >
13°C
=
13°C >
T0 >
7°C
=
7°C >
T0 >
0°C
=
T0 <
0°C
T0: Outdoor temperature
3. ANTIFREEZING CONTROL (Cooling and Dry mode)
The compressor frequency is decrease on cooling & dry mode when the indoor heat exchanger
temperature sensor detects the temperature lower than Temperature .
Then, the anti-freezing control is released when it becomes higher than Temperature .
(Table 14 : Anti-freezing Protection Operation / Release Temperature)
Outdoor temperature
Over than
10°C
*1
or 12°C
*2
Less than
10°C
*1
or 12°C
*2
*1. When the temperature rises.
*2. When the temperature drops.
Outdoor unit fan speed (UP / LO)
850/ 780 rpm
780/ 780 rpm
350/ 350 rpm
13.0A / 12.5A
15.0A / 14.5A
18.0A / 17.5A
850/ 750 rpm
520/ 520 rpm 350/ 350 rpm
780/ 780 rpm
11.0A / 10.5A 11.0A / 10.5A 11.0A / 10.5A 11.0A / 10.5A 11.0A / 10.5A 11.0A / 10.5A
14.5A / 14.0A 14.5A / 14.0A
18.0A / 17.5A
15.0A / 14.5A
17.5A / 17.0A
17.5A / 17.0A
14.0A / 13.5A 14.0A / 13.5A
Temperature
Temperature
4°C
05-21
200/ 200 rpm
170/ 170 rpm
150/ 150 rpm
13.0A / 12.5A
15.0A / 14.5A
Outdoor unit fan speed (UP / LO)
280/ 280 rpm
400/ 0 rpm
12.0A / 11.5A 12.0A / 11.5A
14.0A / 13.5A
7°C
13°C
350/ 0 rpm
300/ 0 rpm
12.0A / 11.5A
11.5A / 11.0A