FoxGate S9816-GS8 Manual

S98xx series

Advertisement

CHAPTER 1 INTRODUCTION ...................................................... 2
1.1.1 Overview ..................................................................................................... 3
1.1.2 Features and Benefits ................................................................................ 3
1.5.1 Front Panel ................................................................................................ 12
1.5.2 Back Panel ................................................................................................ 13
1.5.3 DC Power Input ........................................................................................ 13
1.5.4 Status LEDs .............................................................................................. 13
1.5.5 Front Panel Port Description .................................................................. 16
1.5.6 Back Panel Port Description ................................................................... 16
CHAPTER 2 HARDWARE INSTALLATION ................................ 18
2.1.1 Environmental Requirements ................................................................. 18
2.1.2 Installation Notice .................................................................................... 21
2.1.3 Security Warnings .................................................................................... 21
2.2.1 Verify the Package Contents ................................................................... 22
2.2.2 Required Tools and Utilities .................................................................... 22
2.3.1 Installing the Switch ................................................................................ 22
2.3.2 Connecting Console ................................................................................ 24
2.3.3 SFP Transceiver Installation ................................................................... 24
2.3.4 XFP Transceiver Installation ................................................................... 25
2.3.5 Copper Cable/Fiber Cable Connection .................................................. 25
2.3.6 Power Supply Connection ...................................................................... 26
Content
.................................................................................... 2
................................................................... 11
................................................................ 12
.......................................................................... 18
................................................................ 22
............................................................................ 22
........................................... 5
.................................. 8
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S9816-GS8 and is the answer not in the manual?

Questions and answers

Summary of Contents for FoxGate S9816-GS8

  • Page 1: Table Of Contents

    Content CHAPTER 1 INTRODUCTION ............2 1.1 P ..................2 RODUCT RIEF 1.1.1 Overview ..................... 3 1.1.2 Features and Benefits ................3 1.2 S9816-GS8/X2 T ........... 5 ECHNICAL SPECIFICATIONS 1.3 S9820/44-GS4M2T2 T ........8 ECHNICAL SPECIFICATIONS 1.4 P ..............11...
  • Page 2: Chapter 1 Introduction

    Chapter 1 Introduction 1.1 Product Brief S98XX series switch include six models: S9816-GS8: Figure 1-1 S9816-GS8 Switch S9816-GS8X2: Figure 1-2 S9816-GS8X2 Switch S9820-GS4M2T2: Figure 1-3 S9820-GS4M2T2 Switch S9844-GS4M2T2...
  • Page 3: Overview

    Figure 1-4 S9844-GS4M2T2Switch 1.1.1 Overview S98XX series switch are 10Gb Ethernet routing switch. S9816-GS8 has 24 fixed 1000Mb ports (16 1000Mb fiber ports and 8 1000Mb COMBO ports). S9816-GS8X2 has 24 fixed 1000Mb ports (16 1000Mb fiber ports and 8 1000Mb COMBO ports) and 2 fixed 10Gb XFP ports.S9820-GS4M2T2 has 24 fixed 1000Mb ports (20 1000Mb...
  • Page 4  3D-SMP Ready S98XX series are up to the mustard of Self-defending security region management strategy according to FoxGate. It is supported interaction with some security system such as firewall, IDS, etc. It can defense the virus and aggress effectively from the extranet and internet. Thus enhance the security and stability of...
  • Page 5: S9816-Gs8/X2 Technical Specifications

    WEB interface and RMON. It can mail the correlative sensitive information to the administrator abide by SMTP protocol. S98XX series support SSH protocol, ensure the configuration management security of the switch. It is adopted the FoxGate centralized web management system „LinkManager‟ for unified management expedienty and compactly.
  • Page 6 Item S9816-GS8 S9816-GS8X2 PIM-SM/DM for IPv6, MLD for IPv6(v1), MLDv1/v2, MLD Snooping 6to4 Tunnels, configured Tunnels , ISATAP etc, Carry out by hardware completely, have no effect for performance. Each port has 8 queues. Support SP, WRR, SWRR, DWRR, SDWRR queue scheduling algorithm.
  • Page 7 Item S9816-GS8 S9816-GS8X2 Support Port Limit(bandwidth management) Support broadcast storm control Support Port Mirror(CPU Port Mirror, ingress or egress unilateralism/ bidirectional, one-to-one, many-to-one, stride board) Support Flow Control: HOL prevent head-packet block, half-duplex back pressure, full-duplex IEEE802.3x, Support Port aggregation IEEE802.3ad(LACP),...
  • Page 8: S9820/44-Gs4M2T2 Technical Specifications

    Monitoring the Task exception, Memory exception, CPU monitoring and fault utilance, Stack exception, Switching-chip exception, check-up board temperature exception etc. And giving an alarm Centralized It is adopted the FoxGate centralized web management Management software „LinkManager‟ for unified management. Software 1.3 S9820/44-GS4M2T2 Technical specifications Item...
  • Page 9 Item S9820-GS4M2T2 S9844-GS4M2T2 ARP, ARP Proxy Layer ICMPv6, ND Protocol RIPng, OSPFv3, BGP4+ Specification PIM-SM/DM for IPv6, MLD for IPv6(v1), MLDv1/v2, MLD Snooping, s (IPv6) 6to4 Tunnels, configured Tunnels , ISATAP Carry out by hardware completely, have no effect for performance. Each port has 8 queues.
  • Page 10 Item S9820-GS4M2T2 S9844-GS4M2T2 Support Port Limit(bandwidth management) Support broadcast storm control Support Port Mirror(CPU Port Mirror, ingress or egress unilateralism/ bidirectional, one-to-one, many-to-one, stride board) Support Flow Control: HOL prevent head-packet block, half-duplex back pressure, full-duplex IEEE802.3x, Support Port aggregation IEEE802.3ad(LACP), port-to-port GEC/FEC, each trunk can up to 8 ports, support load equipoise Support IPv4/IPv6 DHCP Client, IPv4/IPv6 DHCP Relay, IPv4/IPv6 DHCP...
  • Page 11: Physical Specifications

    Monitoring the Task exception, Memory exception, CPU utilance, Stack monitoring exception, Switching-chip exception, board temperature exception etc. fault And giving an alarm check-up Centralized It is adopted the FoxGate centralized web management software „LinkManager‟ for unified management. Management Software 1.4 Physical Specifications  Management Port...
  • Page 12: Description Of Hardware

    Min. 80, 000 Hours MTBF 1.5 Description of Hardware 1.5.1 Front Panel S9816-GS8 has 16 1000Mb fiber SFP ports, 8 1000Mb Combo ports (8 RJ-45 and 8 SFP ports), 1 Console port and 66 LEDs. The front panel of S9816-GS8 is shown below:...
  • Page 13: Back Panel

    1.5.3 DC Power Input S98XX supports AC/DC power redundancy. The figure below shows the DC Power Input of S9816-GS8/26. -48 DC power‟s pin-outs are distributed as below: Figure 1-11 S98XX series DC Power Input Pin-outs Distribution DC power has 3 pin-outs:...
  • Page 14 S98XX series include a display panel and port indications that simplify installation and network troubleshooting. The LEDs, which are located on the front panel for easy viewing, are shown below and described in the following table. Table 1.1 S9816-GS8/X2LEDs Panel Status...
  • Page 15 Panel Status Description Symbol On means ports are in the link state On /Blink(Yellow) of 10M or 100M; Blink means system is activating On means ports are in the link state Link/Activity On /Blink(Green) of 1000M; Blink means system is activating No flow go through the port On (Green) Power is operating normally.
  • Page 16: Front Panel Port Description

    1.5.5 Front Panel Port Description S9816-GS8/X2provides 16 1000Mb fiber SFP ports and 8 1000Mb Combo ports (8 RJ-45 or 8 SFP ports). S9816-GS8X2 also provides 2 10Gb XFP ports. S9820-GS4M2T2 provides 4 1000Mb Combo ports (4 RJ-45 or 4 SFP ports) and 20 RJ-45 1000Mb ports.
  • Page 17 Figure 1-12 close loop stack port link In the line mode topology stack, only one stack link to another switch, applying the intercommunication among the stacks. In the close loop stack, an extra stack line link the top and bottom switch to form a close loop structure. The close loop stack supports one redundant route for stack link to avoid the disconnect.
  • Page 18: Chapter 2 Hardware Installation

    Chapter 2 Hardware Installation 2.1 Installation Notice To ensure the proper operation of S98XX series and your physical security, please read carefully the following installation guide. 2.1.1 Environmental Requirements  The switch must be installed in a clean area. Otherwise, the switch may be damaged by electrostatic adherence.
  • Page 19 below details the threshold value. Average (mg/m³) Max (mg/m³) 0.006 0.03 0.04 0.15 0.05 0.15 0.01 Table 2.2 Environmental Requirements: Particles 2.1.1.2 Temperature and Humidity Although the switch is designed to use 4 fans, the site should still maintain a desirable temperature and humidity.
  • Page 20 2.1.1.3 Power Supply Before powering on the power supply, please check the power input to ensure proper grounding of the power supply system. The input source for the switch should be reliable and secure; a voltage adaptor can be used if necessary. The building‟s circuit protection system should include in the circuit a fuse or circuit-breaker of no greater than 240 V, 10 A.
  • Page 21: Installation Notice

    fans must be provided for an enclosed rack, and devices should not be stacked closely.  When mounting devices in an open rack, care should be taken to prevent the rack frame from obstructing the switch ventilation openings. Be sure to check the positioning of the switch after installation to avoid the aforementioned.
  • Page 22: Installation Preparation

    Potential risk include: Electric leakage, Power supply arcing, Power line breakage, Imperfect earth, Overload circuit and Electrical short circuit. If electric shock, fire, electrical short circuit occurs, please cut off the electricity supply and alarm rapidly. Rescue the injured person in the contingency under inherently safe, give the injured person proper first aid treatment according to the injury state, and seek help from the Medical Emergency using various ways.
  • Page 23 Figure 2-1 S9816-GS8 Install sketch map on the rack Figure 2-2 S9816-GS8X2 Install sketch map on the rack Figure 2-3 S9820-GS4M2T2 Install sketch map on the rack Figure 2-4 S9844-GS4M2T2 Install sketch map on the rack Please mount S98XX series on the 19‟‟ rack as below: 1.
  • Page 24: Connecting Console

    switch for good air circulation. Caution! The brackets are used to fix the switch on the rack. They can‟t serve as a bearing. Please place a rack shelf under the switch. Do not place anything on top of the switch. Do not block the blowholes on the switch to ensure the proper operation of the switch.
  • Page 25: Xfp Transceiver Installation

    The procedure for installing the SFP transceiver is shown below: Step 1: Put on a ESD wrist strap (or antistatic gloves). Step 2: Insert the SFP transceiver to the guide rail inside the fiber interface line card. Do not put the SFP transceiver up-side-down. Step 3: Push the SFP transceiver along the guide rail gently until you feel the transceiver snap into place at the bottom of the line card.
  • Page 26: Power Supply Connection

    Caution! Please verify the sign above the port to ensure using the right port. Connecting to wrong ports might damage the switch. Fiber cables should be connected as below: Step 1: Remove the protective plug from the SFP/XFP fiber transceiver bore; Remove the protective cap from one end of the fiber cable.
  • Page 27 Figure 2-6 Attaching power cable to S98XX 1. Insert one end of the power cable provided in the accessory kit into the power source socket (with overload and leakage protection), and the other end to the power socket in the back panel of the switch. 2.

This manual is also suitable for:

S9820-gs4m2t2S9816-gs8x2

Table of Contents