Choose this function to measure from -500.00 to +999.00 mV, 0.000 to 20.000 V, 1.000 to 5.000 V,
0.0% to 100.0% of 1 to 5 Volts or 0.00 to 60.00 V.
Move the power switch
the knob to scroll through the settings and press the knob to make your selection. Select V for the
FUNCTION and 999 mV, 5 V, 20 V or 60 V for the RANGE.
Connect the red input lead (+) of the PIE Model 235 to the more positive point of the break and the
black input to the more negative point.
The PIE Model 235 measures the input signal and constantly updates the display with the current
reading. Move the EZ-CHECK switch
lowest reading. Press and hold the knob
Signals above the maximum scale are limited by protection circuitry with "OVER RANGE" flashed on
the display and the red OVERLOAD LED lit.
Page 6
0.561.8187
Reading DC Voltages
w
to READ then Double Click the EZ-DIAL knob to get into the Menu. Turn
q
to MAX to see the highest reading and to MIN to see the
to clear the MAX and MIN readings.
e
+
2
-
1
4.985
V
MAX
60.00
Signals exceeding ±60.00 VDC are indicated
by i on the display.