Hide thumbs Also See for Physilog 5:

Advertisement

Thank you for purchasing Physilog®5, the Swiss quality movement sensor. This manual
introduces how to use the different features of the sensor.

Table of Contents

1.Physilog®5 elements...........................................................................................................................................2
2.Charging.................................................................................................................................................................2
3.Recording with Physilog®5...............................................................................................................................3
3.1 Standalone measurement............................................................................................................................3
3.2 Live Bluetooth stream of data....................................................................................................................3
3.3 Synchronous measurement with multiple Physilog®5......................................................................3
3.4 Extension board (coming in march 2017)...............................................................................................4
4.Data Analysis........................................................................................................................................................4
5.Practical Considerations....................................................................................................................................5
5.1 Fixation................................................................................................................................................................5
5.2 Handling / Maintenance..............................................................................................................................5
5.3 How to update Date and Time of the Physilog®5................................................................................7
5.4 How to update firmware of Physilog®5 with nRF Connect..............................................................7
5.5 Sensor specifications.....................................................................................................................................8
5.6 Battery autonomy estimations.................................................................................................................9
5.7 Troubleshoot...................................................................................................................................................10
6.Limited Warranty & Support Policy.............................................................................................................11
4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND
User manual
1

Advertisement

Table of Contents
loading

Summary of Contents for Gait up Physilog 5

  • Page 1: Table Of Contents

    5.4 How to update firmware of Physilog®5 with nRF Connect..............7 5.5 Sensor specifications.............................8 5.6 Battery autonomy estimations.........................9 5.7 Troubleshoot..............................10 6.Limited Warranty & Support Policy......................11 4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND...
  • Page 2: Physilog®5 Elements

    The Physilog® 5 should be charged using USB at 4.2V, 100mA. For charging, the ambient temperature must lie between 0°C and 45°C. 4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND...
  • Page 3: Recording With Physilog®5

    Multiple sensor measurement start via Bluetooth command will soon be available. 4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND...
  • Page 4: Extension Board (Coming In March 2017)

    Note: Bluetooth 4.0 or higher is required on the mobile device to be able to communicate with Physilog®5. 4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND...
  • Page 5: Practical Considerations

    - Make sure to know which Physilog® file corresponds to which trial for your analysis – Last digits of file name are automatically incremented (exceeding 999 and firmware update 4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND...
  • Page 6 à Physilog®5 doivent être «très basse tension de protection» et «source à tension limité» comme décrit dans normes suivantes: IEC60950-1:2005+/A1:2010 EN60950- 1:2006+/A11:2009+/A1:2010+/A12:2011 4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND...
  • Page 7: How To Update Date And Time Of The Physilog®5

    - Disconnect the Physilog® by clicking on “Disconnect” and close the tab of the Physilog®5 - Plug the Physilog® to the computer and update the date and time (see above) 4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND...
  • Page 8: Sensor Specifications

    Lithium Ion Polymer Accumulators 3.7V 140mAh Plastic Enclosure ABS Polylac® PA-757 Biocompatible with bi-color LED and 8mm button 4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND...
  • Page 9: Battery Autonomy Estimations

    3D Gyroscope Barometric pressure Hours 256Hz 256Hz 64Hz 256Hz *Autonomy measured for firmware version 0.0.9 at room temperature 4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND...
  • Page 10: Troubleshoot

    (www.gaitup.com/support2017) or write an email to: contact@gaitup.com. Please indicate Physilog® serial number and describe the problem in as much detail as possible. 4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND...
  • Page 11: Limited Warranty & Support Policy

    Consulting is subject to acceptance of a formal statement of work. 4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND...
  • Page 12 Please contact us at: EPFL Innov’ Park - C CH-1015 Lausanne tel: +41 21 633 7527 mail: contact@gaitup.com web: www.gaitup.com 4 jan.2017 - Physilog 5 user manual.pdf - v1.1 - Check www.gaitup.com for the latest version. Copyright �2017 Gait Up SA. CH-1015 SWITZERLAND...

Table of Contents