SIGLENT SPA1010 Series User Manual
SIGLENT SPA1010 Series User Manual

SIGLENT SPA1010 Series User Manual

Hide thumbs Also See for SPA1010 Series:

Advertisement

Quick Links

User Manual

SPA1010 Series Power Amplifier
UM60010-E01A
2015 SIGLENT TECHNOLOGIES CO,.LTD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPA1010 Series and is the answer not in the manual?

Questions and answers

michael
February 28, 2025

should the red light on the front panel be on or off?

1 comments:
Mr. Anderson
February 28, 2025

The red light on the front panel of the SIGLENT SPA1010 Series should be off under normal operation. If it is on, it indicates that the overcurrent protection is enabled.

This answer is automatically generated

Summary of Contents for SIGLENT SPA1010 Series

  • Page 1: User Manual

    User Manual SPA1010 Series Power Amplifier UM60010-E01A 2015 SIGLENT TECHNOLOGIES CO,.LTD...
  • Page 2 SIGLENT Declaration Copyright © by SIGLENT TECHNOLOGIES CO,.LTD. All rights reserved. Contents in this Manual are not allowed to copy, extract and translate before being allowed by SIGLENT. SPA1010 User Manual I...
  • Page 3 SIGLENT General Safety Summary Carefully read the following safety precautions to avoid person injury and prevent damage to the instrument and any products connected to it. To avoid potential hazards, please use the instrument as specified. Only qualified technician should perform service procedures...
  • Page 4: Safety Terms And Symbols

    SIGLENT Safety Terms and Symbols Terms used on the instrument. Terms may appear on the instrument: DANGER: Indicates an injury or hazard that may be immediately happen. WARNING: Indicates an injury or hazard that may be not immediately happen. CAUTION: Indicates that a potential damage to the instrument or other property might occur.
  • Page 5: Spa1010 Power Amplifier Introduction

    Waveform Generators, with up to 1MHz full power bandwidth and higher than 90 V/ s slew rate, which can be used in fast constructions of a test platform in connection with all SIGLENT SDG series products, and as a single power amplifier in coordination with other generators.
  • Page 6: Table Of Contents

    General Inspection ....................1 The Front Panel ......................2 The Rear Panel ......................3 Operation ....................4 How to set the output status ..................4 Application Examples ................Power Component Measurements ................ 5 Troubleshooting ..................6 Specifications ..................Contact SIGLENT ................... 9 SPA1010 User Manual...
  • Page 7: Quick Start

    The consigner or carrier will be responsible for damages to the instrument resulting from shipment. SIGLENT would not provide free maintenance or replacement. 2. Inspect the instrument.
  • Page 8: The Front Panel

    SIGLENT The Front Panel Status Indicator Signal Output Gain Select Output Switch Figure 1- 1 SPA1010 Front Panel CAUTION The output impedance of the instrument Zo is less than 2 , and the range of output voltage is -13V ~ +13V(RL=1K ).
  • Page 9: The Rear Panel

    SIGLENT The Rear Panel Fan aperture Signal Input Power In Figure 1- 2 SPA1010 Rear Panel Power In Please plug with DC (12V, 4A) using the power adapter provided in the accessories. CAUTION Do not use any other adapters to supply power for the SPA1010, or else it may cause degradation or perpetual damage.
  • Page 10: Operation

    SIGLENT Operation How to set the output status For the details of each selection on the front panel of SPA1010, see table below: Function Setup Explanation Sets the output gain. The input range of Voltage Gain X1, X10 signals is different in different gain setting.
  • Page 11: Application Examples

    SIGLENT Application Examples Power Component Measurements SPA1010 could be used as the power amplifier of a generator to evaluate the performance of a power component. In virtue of its wide bandwidth and high speed output, users can evaluate or test the components through various waves, pulses and arbitrary waves.
  • Page 12: Troubleshooting

    1 Check if the power is correctly connected 2 Check if the power switch is enable 3 After above checks, restart the instrument; 4 If it can’t work properly, please contact SIGLENT for help. 2. Circuit Protection The instrument will start overcurrent protection or...
  • Page 13: Specifications

    SIGLENT Specifications All specifications listed in the table below can be met under following two conditions unless where noted: The instrument has been continuously operated for 30 minutes at the stated temperature. All the specifications are guaranteed except for the one marked “typical”.
  • Page 14 SIGLENT the capacitive load Overtemperature Protection Gate Power In Rated Voltage 12 Vpp Rated Voltage Others Working Temperature 0 ~ 40 Dimension( WxHxD) 193 mm x 122 mm x 42 mm Net Weight 540 g Note 1 The output power of SPA1010 is limited by frequency. When input frequency between 500Hz to 200 KHz, the SPA1010 will deliver 10 watts into a 8 load.
  • Page 15: Contact Siglent

    SIGLENT Contact SIGLENT SIGLENT TECHNOLOGIES CO.,LTD Address 3/F, building NO.4, Antongda Industrial Zone, 3rd Liuxian Road, Bao’an District, Shenzhen, P.R.China Tel 0086-755-3661 5186 E-mail sales@siglent.com Http://www.siglent.com SPA1010 User Manual...