Section 4: Circuit Adjustments; Setting Service Adjustment Mode; 4-1.1. Service Adjustment Mode In; 4-1.2. Service Adjustment Mode Memory - Sony TRINITRON KV-30HS510 Service Manual

Hide thumbs Also See for TRINITRON KV-30HS510:
Table of Contents

Advertisement

ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER

Use the Remote Commander (RM-Y191) to perform the circuit adjustments in this section.
Test Equipment Required:

4-1. SETTING SERVICE ADJUSTMENT MODE

1. Standby mode (Power off).
2. Press the following buttons on the remote commander within a
second of each other:
Channel 5
DISPLAY

4-1.1. SERVICE ADJUSTMENT MODE IN

Disp.
(Item)
VP
HSIZ
Mode
3. The CRT displays the item being adjusted.
4. Press 1 or 2 on the Remote Commander to select the item.
5. Press 3 or 6 on the Remote Commander to change the data.
6. Press MUTING then ENTER to write into memory.
4-1.2. SERVICE ADJUSTMENT MODE
MEMORY
Disp.
Item
Item
(Item)
order
data
VP
7
0
SERVICE
TV
HSIZ
7. Press then on the Remote Commander to initialize.
Disp.
Item
(Item)
order
VP
HSIZ
8. DO NOT turn off set until SERVICE appears.

SECTION 4: CIRCUIT ADJUSTMENTS

1. Pattern generator 2. Frequency counter 3. Digital multimeter 4. Audio oscillator
Sound Volume +
Power
Item
Item
order
data
SERVICE
0
7
TV
MUTING
Green
ENTER
Red
Item
data
7
0
WRITE
TV

4-1.3. READING THE MEMORY

1. Enter into Service Mode.
2. Press 0 on the Remote Commander.
3. Press ENTER to read memory.

4-1.4. ADJUSTING THE PICTURE

1. Enter into Service Mode
2. Press 2 or 5 on the remote to select the device item.
3. Press 1 or 4 on the remote to select an item.
4. Press 3 or 6 on the remote to change the data.
5. Press MUTING then ENTER to write into memory.

4-1.5. RESETTING THE DATA

Note: Be careful when using the remote! It will clear and re-initialize
ALL NVM data including defl ection adjustment data if not reset
properly as follows:

4-1.6. RESETTING THE MID NVM DATA

1. Enter into Service Mode.
2. Press 7 , then JUMP , and then press ENTER on the remote.

4-1.7. RESETTING THE SYSTEM NVM DATA

1. Enter into Service Mode.
2. Press 7 , then 9 , and then press ENTER on the remote.

4-1.8. COPY FUNCTION

How to use copy function for DA4 Chassis:
• After writing your adjusted data into NVM MUTING
then ENTER , copy can be made by changing copy data from 0 to
1 then MUTING , ENTER again.
WARNING: DO NOT copy data before writing your corrected data in
NVM. If data is copied before writing corrected data, old
data will be copied.
• CPY1: DF/DQP DATA
• CPY2: CONVERGENCE DATA
— 23 —
KV-30HS510
(CXA2170D-4 Item 6)
(D-CONV Item 13)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents