Troubleshooting - Polaris IQ Turbo Dragon Owner's Manual

Polaris 2010 snowmobile owner's manual
Table of Contents

Advertisement

TROUBLESHOOTING

Engine and Drive Train Troubleshooting
Engine Speed, RPM or Boost is Limited
Probable Cause
Engine Management System RPM
Reduction Mode is activated
Jammed clutch
Jammed track
Jammed or broken chaincase sprocket or
chain
Mechanical failure
Engine Doesn't Turn Over
Probable Cause
Low battery voltage
Loose battery connections
Loose solenoid connections
Engine stop switch is off
Fusible link malfunction
Fuse panel malfunction
Main relay panel malfunction
Mechanical failure
136
Solution
See causes on page 34.
Check for twisted belt or broken spring.
See your dealer.
Remove any foreign objects. Slider may
be melted to the track clips due to lack of
lubrication. Track may be iced up or fro-
zen to the ground.
See your dealer.
See your dealer.
Solution
Recharge the battery to 12.8 VDC.
Check all connections and tighten.
Check all connections and tighten.
Lift the stop switch to the ON position.
See your dealer.
Check condition of fuses. Replace blown
fuses, then see your dealer.
See your dealer.
See your dealer.