IMPORTANT SAFETY INSTRUCTIONS

WARNING: Failure to observe these instructions can cause
personal injury to machine operator or bystanders.
WARNING: Fire or explosion hazard.
NEVER operate this machine in an
explosive atmosphere (grain dust,
flammable liquids or fumes, etc.).
WARNING: Orange Oil (D-limonene) is not compatible with the plastics used in NSS
automatic scrubbers and the Sidekick Chemical Metering System. Use of D-limonene may
result in damage to the machine.
WARNING: This product contains a chemical known to the state of California to cause
cancer and birth defects or other reproductive harm.
INTENDED USE
This machine is intended for commercial use,
scrubbing floors in an indoor environment. NSS does
not recommend using these machines for any other
purpose.
FOR SAFETY
ALWAYS read and understand all instructions before
operating or servicing machine.
ALWAYS use this machine ONLY as described in this
manual.
NEVER attempt to operate this machine unless you
have been trained in its operation.
NEVER allow an untrained person to operate this
machine.
NEVER attempt to operate this machine if it is not
working properly or has been damaged in any
manner.
NEVER disconnect or modify any switches or safety
devices (circuit breaker).
NEVER drop or insert any object into any machine
opening.
NEVER operate this machine with any air opening
blocked. Keep all air openings free of dust, lint, hair,
etc.
NEVER pick up anything that is burning or smoking,
such as cigarettes, matches or hot ashes.
NEVER spray this machine with water or any liquids.
NEVER allow the vacuum motor or battery-charging
plug to get wet or a short may occur.
NEVER operate this machine when the battery
charger is plugged in.
NEVER operate this machine with the side skirt
removed.
NEVER allow this machine to be used as a toy. Close
attention is necessary when used by or near children.
ALL REPAIR SERVICE MUST BE PERFORMED BY AN NSS AUTHORIZED DISTRIBUTOR /
SERVICE STATION USING ONLY NSS ORIGINAL EQUIPMENT PARTS.
SAVE THESE INSTRUCTIONS
OPERATION MANUAL
CHAMP 3329 RB
ORIGINAL INSTRUCTIONS 
WARNING: Fire or explosion hazard.
NEVER attempt to pick up flammable or
combustible materials or use such
materials in tanks.
ALWAYS wear clean tennis shoes or "non-slip"
shoes. Leather soled shoes will be extremely slippery
when wet.
ALWAYS keep face, fingers, hair or any other body
part or loose clothing away from any machine opening
or moving part (revolving brush, pad driver, or vacuum
motor).
ALWAYS turn the machine off when attaching pads
or brushes.
ALWAYS remove keys when this machine is left
unattended.
NEVER turn on machine unless sitting in the
operators seat.
NEVER climb on machine when it is turned on.
NEVER use machine to transport passengers other
than the operator.
ALWAYS be sure that the ramp is secured to the
vehicle before attempting to load / unload.
ALWAYS use extreme caution when operating the
machine on a ramp or loading / unloading this
machine into or out of a truck / trailer. Use extreme
caution if the ramp is wet, oily, or covered with
cleaning chemicals.
NEVER stop or turn the machine on a ramp or
incline.
NEVER attempt to climb a grade or operate this
machine on a ramp or incline of more than 3%.
NEVER park or store the machine near a dock, on
ramps, near a furnace, boiler, open flame, or other
high heat source.
NEVER allow this machine to freeze.
NEVER expose the machine to rain, snow, or
extreme temperatures.
NEVER store any items on the machine.
ALWAYS store this machine indoors in a dry, cool
area.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CHAMP 3329 RB and is the answer not in the manual?

Questions and answers

Summary of Contents for NSS CHAMP 3329 RB

  • Page 1: Important Safety Instructions

    WARNING: Orange Oil (D-limonene) is not compatible with the plastics used in NSS automatic scrubbers and the Sidekick Chemical Metering System. Use of D-limonene may result in damage to the machine.
  • Page 2  ALWAYS keep flammable materials away from charger. the batteries and the electrical system. ALL REPAIR SERVICE MUST BE PERFORMED BY AN NSS AUTHORIZED DISTRIBUTOR/ SERVICE STATION USING ONLY NSS ORIGINAL EQUIPMENT PARTS SAVE THESE INSTRUCTIONS...
  • Page 3: Grounding Instructions

    NOTE: In Canada, the use of a temporary adaptor may not be permitted by Canadian electrical code. ALL REPAIR SERVICE MUST BE PERFORMED BY AN NSS AUTHORIZED DISTRIBUTOR/ SERVICE STATION USING ONLY NSS ORIGINAL EQUIPMENT PARTS.
  • Page 4: Noise And Vibration

     Down is on, lowering brushes to heavy pressure. NOISE AND VIBRATION  Brushes only come on when machine is moving in forward or reverse. NOISE Sound pressure level at Operator 70 dB(A) Traction Speed Switch - 2 Positions: position ...
  • Page 5: Machine Operation

     Place “Wet Floor” warning signs in area being cleaned. performance or service life.   Consult your local NSS distributor for more complete The squeegee rises automatically when the machine is in procedures and chemical advice. reverse.  Squeegee springs add pressure to floor. There are 3...
  • Page 6: Machine Maintenance

     Empty and rinse clean the recovery tank. containers, and some smaller round containers.  Remove and rinse clean the squeegee assembly. o Empty F-style containers are available from NSS, ***NOTE: prolonged exposure to some wax stripper order part #9590171.
  • Page 7: Battery Charger

    NSS factory. The standard battery type, Replace the brushes when they are 7/16 in. (11mm.) normally supplied by NSS, is the Flooded (wet) cell lead in length. acid battery. Gel and AGM sealed batteries may also be available at customer request.
  • Page 8 The standard setting for the onboard battery charger 3. Reinstall the top cover. is Flooded/AGM. EXCEPTION: If your machine was ordered from NSS equipped with Gel batteries, then the charger was configured for Gel batteries at the factory. Configuring the Charger for Gel batteries.
  • Page 9 1. Remove the top cover g. ALWAYS check the electrolyte level about every 3 2. Pull the jumper from the storage location or 4 charge/discharge cycles BEFORE (position 2), and install the jumper at position 1. CHARGING. 3. Reinstall the top cover. h.
  • Page 10 TRIO+: Scrubber System Diagnostic Codes Scrubber System Faults External to TRIO+ Code Fault Description Corrective Action 0810 Throttle fault-1.0 For all Throttle Diagnostic Codes: 0811 Throttle max wiper difference error. 1- Check the throttle wiring for shorts or opens. Repair or replace as necessary. 0812 Throttle max pull down difference error.
  • Page 11 2C02 Soft battery lockout occurred. Battery Charge too low. Recharge battery. 2C03 Soft battery lockout 2 occurred. Battery Charge too low. Recharge battery. 2F01 Tiller displaced error. Throttle displaced on Power-up. Release throttle and then re-engage throttle. Check Potentiometer settings (neutral). 3A00 Bad settings.
  • Page 12 Possible Internal TRIO+ Faults Code Code Code Code Corrective Action 0003 1800 3104 3603 For All Internal TRIO + Diagnostic Codes: 0100 1802 3105 3608 1 - Turn Off Key switch and disconnect batteries. 0204 1B20 3200 3609 2 - Wait 1 minute. 0705 1B21 3201...
  • Page 13: Troubleshooting

    Trouble Shooting PROBLEM CAUSE SOLUTION No Solution The solution valve is closed. Open the solution valve. Flow. Water solenoid valve not open. Charge the battery. Obstruction in the solution hose. Remove the obstruction. Solution valve or cable damaged. Repair / replace the valve cable. Solution tank is empty.
  • Page 14 NOTES...
  • Page 15 NOTES...
  • Page 16 ® Enterprises, Inc. 3115 Frenchmens Road, Toledo, Ohio 43607 PHONE (419) 531-2121 FAX (419) 531-3761 NSS Asia Limited Shanghai Building 188, Lane 1421, East Zhuan Xin Road, Min Hang District, Shanghai, China 201108 PHONE: (021) 61371251 FAX: (021) 61371252 CHAMP 3329 Operation Manual - 9097632 - Orig. 02-05 – Rev J 07-14...

This manual is also suitable for:

Champ 3529 rb

Table of Contents