Download Print this page

ABLE 6 Series Installation & Maintenance Instructions page 5

Pressure switch

Advertisement

Models
1/2 NPT
Models S1261B-S160B
1/4 NPT
Models 258-274
RECOMMENDED PRACTICES AND WARNINGS
United Electric Controls Company recommends careful consideration of the following factors when
specifying and installing UE pressure and temperature units. Before installing a unit, the Installation
and Maintenance instructions provided with unit must be read and understood.
To avoid damaging unit, proof pressure and maximum temperature limits stated in literature
and on nameplates must never be exceeded, even by surges in the system. Operation of the unit
up to maximum pressure or temperature is acceptable on a limited basis (e.g., start-up, testing)
but continuous operation must be restricted to the designated adjustable range. Excessive cycling
at maximum pressure or temperature limits could reduce sensor life.
A back-up unit is necessary for applications where damage to a primary unit could
endanger life, limb or property. A high or low limit switch is necessary for applications where a
dangerous runaway condition could result.
The adjustable range must be selected so that incorrect, inadvertent or malicious setting
at any range point cannot result in an unsafe system condition.
Install unit where shock, vibration and ambient temperature fluctuations will not damage
unit or affect operation. Orient unit so that moisture does not enter the enclosure via the electri-
cal connection. When appropriate, this entry point should be sealed to prevent moisture entry.
Unit must not be altered or modified after shipment. Consult UE if modification is neces-
sary.
Monitor operation to observe warning signs of possible damage to unit, such as drift in
set point or faulty display. Check unit immediately.
Preventative maintenance and periodic testing is necessary for critical applications where
damage could endanger property or personnel.
For all applications, a factory set unit should be tested before use.
Electrical ratings stated in literature and on nameplate must not be exceeded. Overload
on a switch can cause damage, even on the first cycle. Wire unit according to local and national
electrical codes, using wire size recommended in installation sheet.
Do not mount unit in ambient temp. exceeding published limits.
LIMITED WARRANTY
Seller warrants that the product hereby purchased is, upon delivery, free from defects in material
and workmanship and that any such product which is found to be defective in such workmanship
or material will be repaired or replaced by Seller (Ex-works, Factory, Watertown, Massachusetts.
1/4 NPT
Models 126-160
1/4 N P
Models 354-364, 680
INCOTERMS); provided, however, that this warranty applies only to equipment found to be so
defective within a period of 24 months from the date of manufacture by the Seller. Seller shall
not be obligated under this warranty for alleged defects which examination discloses are due to
tampering, misuse, neglect, improper storage, and in any case where products are disassembled
by anyone other than authorized Seller's representatives. EXCEPT FOR THE LIMITED WARRANTY
OF REPAIR AND REPLACEMENT STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER
WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR ANY PARTICULAR PURPOSE.
LIMITATION OF SELLER'S LIABILITY
SELLER'S LIABILITY TO BUYER FOR ANY LOSS OR CLAIM, INCLUDING LIABILITY INCURRED IN
CONNECTION WITH (I) BREACH OF ANY WARRANTY WHATSOEVER, EXPRESSED OR IMPLIED, (II)
A BREACH OF CONTRACT, (III) A NEGLIGENT ACT OR ACTS (OR NEGLIGENT FAILURE TO ACT) COM-
MITTED BY SELLER, OR (IV) AN ACT FOR WHICH STRICT LIABILITY WILL BE INPUTTED TO SELLER,
IS LIMITED TO THE "LIMITED WARRANTY" OF REPAIR AND/OR REPLACEMENT AS SO STATED IN
OUR WARRANTY OF PRODUCT. IN NO EVENT SHALL THE SELLER BE LIABLE FOR ANY SPECIAL,
INDIRECT, CONSEQUENTIAL OR OTHER DAMAGES OF A LIKE GENERAL NATURE, INCLUDING, WITH-
OUT LIMITATION, LOSS OF PROFITS OR PRODUCTION, OR LOSS OR EXPENSES OF ANY NATURE
INCURRED BY THE BUYER OR ANY THIRD PARTY.
UE specifications subject to change without notice.
U N I T E D E L E C T R I C
C O N T R O L S
P.O. Box 9143, Watertown, MA 02471-9143 USA
617 926-1000 Fax 617 926-2568
http://www.ueonline.com
IM6-02
1/4 NPT
Models 218-230
1/4 NP T
Models 610-614
EMCO5M0203