Do not expose the amplifier to rain or moisture during operation or storage. If the unit does come into contact with moisture, remove the AC power cord immediately and leave it in a suitably dry area to dry. Take precaution before reconnecting to a power supply. Be aware that when any equipment is taken from a cold to humid location, condensation may occur inside. Always allow time for the equipment to attain the same temperature as its environment before reconnecting to a power supply. Pyle 'PEXA' Series Amplifiers www.PyleAudio.com...
Page 3
When the output power exceeds the safe working range of the amplifier, the Clip LEDS 5. CLIP LED are lit. LCD displays: Detailed power at 2ohm/4ohm/8ohm, Limiter, Working mode, Graphic LCD Display 6. Protection (L/R), Level (L/R), Temperature (L/R heatsink), Clip (L/R), Gain (L/R) SIGNAL LEDS in intensity in response to signals up to ‐30dB.‐20dB to ‐10dB LEDS Level LEDS 7. indicate output levels Power Switch 8. This switch turns the amp on and off. Rack Mount / System 9. Integrated mounting and system handling Handles Loaded Select Switch 10. Press the 4/8 Ohm button, to switch between Ohm levels. Pyle 'PEXA' Series Amplifiers www.PyleAudio.com...
Please note the different layout and functions of the 'PEXA' model series rear panels. Built‐in Protection The PEXA amplifiers feature integrated electronic protection including: Soft start function to prevent wave shock at power‐on Delay function for prevention of shock at switch power‐on DC current protection Over‐electric current protection Cut‐wave protection Overheat protection Pyle 'PEXA' Series Amplifiers www.PyleAudio.com...
Page 5
Binding Post 15. securely. Please make sure to respect the speaker polarity when using binding posts. Caution: Output turn off the unit before connecting an audio signal to the binding post to avoid any damage. Voltage 16. Please make sure that your local voltage matches the voltage indicated on the unit. Selector Signal Ground lift switch is used to lift the balanced input connectors' ground/shield from the Signal Ground amplifier's ground. When the signal ground is lifted, the sound source disconnects from the 17. Lift Switch amplifier's ground preventing ground loops which can generate hum and noise. See the signal ground lift switch instructions for more detail. The power amplifier must be connected only with the attached three‐wire safety power cord with protective conductor (non‐fused earthed conductor). This amplifier is made for use with the Power mains voltage labelled on the back of the amplifier only. Check the label on the back panel of the 18. Connection amplifier for the appropriate voltage. Make sure the voltage of your mains outlet is correct. The power voltage is factory set as labelled on the back panel and cannot be change afterwards. Damage caused by connecting the amplifier to Improper AC voltage voids the warranty. SENSITIVITY (*Model: PEXA8000) 19. Selector Switch Allows selection of 0.775V, 1.0V or 1.40V sensitivity. These fans secures enough cooling for your PEXA8000 amplifier. The airflow is front‐to‐rear. The Cooling Fan 20. fan speed is electronically regulated depending on the temperature of the power devices. Pyle 'PEXA' Series Amplifiers www.PyleAudio.com...
Page 6
second screen. By pressing the front‐located 4Ohm / 8Ohm button, the amplifier system will display the selected Ohm value. After a few seconds, the screen will revert to the second display screen listed above. Pyle 'PEXA' Series Amplifiers www.PyleAudio.com...
Hum or buzz is Use a mains tester to ensure the AC audible outlet has a good earth. Power There is an earth problem connected equipment(e.g mixer and amp) from the same AC outlet where possible. Use the LED to ensure the AC outlet has a Excessive signal level somewhere good earth. Power connected equipment in signal chain. from the same AC outlet where possible Distortion is audible Use only high quality cables of the Damaged or poor quality appropriate type, protect them from cables damage and regularly check connections. Damaged or poor quality cables Sound cuts Check all cables and connections, refer to or connectors, connectors not out or is above sections regarding distortion and properly inserted, amp Intermittent temp warning light overheating Pyle 'PEXA' Series Amplifiers www.PyleAudio.com...
Page 8
S/N Ratio: >110dB (Full Power @ 4 Ω) Crosstalk: >80dB (Full Power @ 4 Ω) Crosstalk: >80dB (Full Power @ 4 Ω) Crosstalk: >80dB (Full Power @ 4 Ω) Damping Factor: >350 (1kHz @ 4 Ω) Damping Factor: >350 (1kHz @ 4 Ω) Damping Factor: >600 (1kHz @ 4 Ω) T.H.D. +N: <0.01% (Rated Power, 4 Ω/1kHz) T.H.D. +N: <0.01% (Rated Power, 4 Ω/1kHz) T.H.D. +N: <0.01% (Rated Power, 4 Ω/1kHz) Frequency Response: 10Hz‐50KHz, ‐1.5dB Frequency Response: 10Hz‐50KHz, ‐1.5dB Frequency Response: 10Hz‐50KHz, ‐1.5dB Input Impedance: 10kΩ Unbalanced, 20kΩ Balanced Input Impedance: 10kΩ Unbalanced, 20kΩ Balanced Input Impedance: 10kΩ Unbalanced, 20kΩ Balanced Slew Rate: >65V/us Slew Rate: >65V/us Sensitivity Switch Adjustable: 0.775V, 1.0V, 1.40V Idle Current Draw: 0.5A, 120V Idle Current Draw: 0.5A, 120V Slew Rate: >65V/us LED Indicator Level Range: ‐30dB, ‐20dB, to ‐10dB LED Indicator Level Range: ‐30dB, ‐20dB, to ‐10dB Idle Current Draw: 1.4A, 120V Power Supply: 110‐220V, 50/60Hz Power Supply: 110‐220V, 50/60Hz LED Indicator Level Range: ‐30dB, ‐20dB, to ‐10dB Dimensions (L x W x H): 18.9'' x 13.7'' x 3.5'' Dimensions (L x W x H): 18.9'' x 13.7'' x 3.5'' Power Supply: 110‐220V, 50/60Hz Dimensions (L x W x H): 18.9'' x 16.1'' x 3.5'' Pyle 'PEXA' Series Amplifiers www.PyleAudio.com...