Adjustment - Kenwood X-SE7 Service Manual

Stereo auto reverse cassette deck
Hide thumbs Also See for X-SE7:
Table of Contents

Advertisement

X-SE7/SE7(G)/SE9
Order
Item
Unless otherwise specified, set the respective switches as follow :
TAPE : NORMAL
I. Cassette mechanism section (Recording/play head adjustment)
Demagnetization
< 1 >
and cleaning
Azimuth of the
< 2 >
REC/PLAY head
II. Printed circuit board adjustment (X28-293)
Tape speed
(1)
(normal)
(2)
Playback level
(3)
Bias current
(4)
Recording level
(A) Measurement Equipment Connection
R
L
SYSTEM
CONTROL
AC voltmeter
AG
4

ADJUSTMENT

Input
Output
setting
setting
DOLBY : OFF
TCC-153
LINE OUT
MTT-114
(Lch or Rch)
10KHz, -10dB
TCC-110
(A)
MTT-111
3KHz
TCC-130
(A)
400 Hz
TCC-108A
(A)
12.5KHz, -21dBm
TCC-108A
(A)
400Hz, -21dB
REC
IN
PLAY
OUT
Oscilloscope
KSJ-0816
Deck
Adjustment points
setting
INPUT : REC IN
Power : OFF
Recording head,
Demagnetization,
erase head, capstan,
cleaning, PLAY
pinch roller
PLAY
FWD
PLAY
MOTOR VR.
ƒ MANUAL
ADJUSTMENT
ADJUSTMENT
VALUE
MODE PLAY
UP : [DOLBY] KEY
ƒMANUAL
DOWN : [RVS
TEST MODE
PLAY] KEY
REC and PLAY
CHANGE OF
ƒ MANUAL
ADJUSTMENT
TEST MODE
MODE [CRLS] KEY
REC and PLAY
AC voltmeter
Distortion meter
Adjustment method
OUTPUT : PLAY OUT
Demagnetize the REC/
PLAY head with the
head eraser. Clean the
REC/PLAY head, erase
head, capstan and
pinch roller using a
cotton swab slightly
damped with alcohol.
Adjust the output to
maximum and adjust
the azimuth adjustment
screw for the Lissajous
waveform pattern of
the oscilloscope to
RVS
become close to a 45˚
straight line.
Adjust so ; that the
frequency is 3KHz at
the tape center.
Output level : -1dBs
-21dBm
-21dBm
The method of the manual adjust-
ment mode.
(1) Setting
Shorting the TEST pin of (X28-
)(A/5) TP5 — w — TP4 with the
diode, plug the power cord to the
AC wall let.
(2) Refer to manual adjustment
mode(3-3), if require more
details.
Fig.