Installation of indoor unit
2. Make the power connection wire
go through the cable-cross hole at
the back of indoor unit and then pull
it out from the front side.
3. Remove the wire clip; connect the
power connection wire to the wiring
terminal according to the color;
tighten the screw and then fix the
power connection wire with wire clip.
4. Put wiring cover back
09、12、18、24K
and then tighten the
screw.
N(1)
2
3
5. Close the panel.
green
white
black
red
(yellow-
6. Install the Conduit
(blue)
(brown)
green)
assy.
1) Fix the conduit assy
on the conduit board and
Outdoor unit connection
then let the connection
wire between indoor unit
and outdoor unit go through the conduit.
2) Fix the conduit assy on the chassis with 3 screws.
• Conduit assy consists of conduit, conduit connector and lock nut.(Not the
standard part, which should be purchased by customer.)
• The length of conduit can be calculated according to the length of con-
nection wire.
connection wire
Conduit connector
sleeve
Lock nut
Cable Cross Plate
Conduit
Note:
• All wires of indoor unit and outdoor unit should be connected by a
professional.
• If the length of power connection wire is insufficient, please contact the
supplier for a new one. Avoid extending the wire by yourself.
• For the air conditioner with plug, the plug should be reachable after
finishing installation.
• For the air conditioner without plug, an air switch must be installed in the
line. The air switch should be all-pole parting and the contact parting
distance should be more than 3mm.
29