Page 2
AirDistSys 5000 2 – Operator’s Manual The AirDistSys5000 enables air temperature and low air speed measurements at several points in spaces, as well as for measurement of flow characteristics in jets from air thermal devices. The AirDistSys5000 is wire-less system which makes it convenient for field and laboratory measurements. Many years experience with manufacturing of low velocity thermal anemometers and the latest development in the field of electronic equipment were used in designing of the system.
Page 5
AirDistSys 5000 5 – Operator’s Manual – – SensoAnemo 5120LSF or 5130LSF (with voltage output) max 3m of total cable length SensoCable 57__ SensoCable 56__ to 0-2V or 0-5V input SensoBoxAccu HD (only vel - polinom.) adapter Power Supply adapter (optional) –...
Page 6
AirDistSys 5000 6 – Operator’s Manual SensoAnemo 5140LSF (with current output) SensoCable 5701 (cable length 1m) SensoCable 56__ to 0-2V or 0-5V input SensoBox DH-V (only vel - polinom.) adapter cable length max 30m Power Supply adapter SensoAnemo5100LSF transducer with omnidirectional (spherical) sensor for measurement of air speed (magnitude of velocity vector) sensor.
Page 7
AirDistSys 5000 7 – Operator’s Manual attached basket) can be moved along the probe support and can be locked at certain position by a clamp screw (5). The transducer has a digital output RS485. Thanks optional analog output of velocity, transducer can work also with analog datalogger, A/D converter or any multimeter.
Page 8
AirDistSys 5000 8 – Operator’s Manual • accuracy of temperature: 0.2 °C • sampling rate: 8 Hz • interface: port RS485 • baud rate: 115000 bps • optional analog output: current 0…20 mA, voltage 0-2V or 0-5V only for velocity, non-linear (set of equations) V [m/s]= f(Iv) •...
Page 9
AirDistSys 5000 9 – Operator’s Manual • humidity accuracy: ±2% in range 10…90% RH • long term stability of humidity: <1% RH/year • response time of humidity: <4s • interface: port RS485 • baud rate: 115000 bps • power supply: 3.3…9 VDC...
Page 10
AirDistSys 5000 10 – Operator’s Manual transducer (see picture below). The red diode by the socket B will be ON when a power supply adapter is connected to the mains socket. Connecting to the measuring system: max. 8 to the next SensoBox Adapter max.
Page 11
AirDistSys 5000 11 – Operator’s Manual SensoBeeUSB receiver by the cable. If the power supply is plugged into the mains socket, the PS diode lights up. The RF diode is blinking when the RF module is turned on, ie. 2-way switch is in RF position.
Page 12
AirDistSys 5000 12 – Operator’s Manual The tripod consists of the following parts presented in the photos below. The way of assembling of the tripod is shown in the photos below. Note that the tubes have been twisted in the order corresponding to the incisions D1-D3.
Page 13
AirDistSys 5000 13 – Operator’s Manual The rail-mounted grip enables to fix the devices equipped with rail clamps, so as: SensoBee wire-less receiver, SensoBox adapter, SensoBar transducer, SensoData dataloger. 1. Power on your computer and boot to Windows. 2. Insert the CD-ROM in your CD drive, choose setup.exe in folder AirDistSys_Inst and run.
Page 14
• try to reassign COM port to a unused port number • click OK when finished. • The AirDistSys 5000 program makes possible for: automatic scanning of the configuration of the measuring system calculating average temperature, average and standard deviation of air speed, turbulence intensity,...
Page 15
AirDistSys 5000 15 – Operator’s Manual • Measuring data is being shown on the front panel as: Running Data Results are displayed every 2 seconds with the chosen averaging time. Averaging Time determines the time of calculating an average of the measurement results. Averaging is continuous, i.e. the oldest result is being replaced with the youngest result in the cycle of averaging.
Page 16
AirDistSys 5000 16 – Operator’s Manual Time, min Results Recorded results are averaged for interval time 0÷1 min – preliminary results Recorded results are averaged for interval time 0÷2 min– preliminary results Recorded results are averaged for interval time 0÷3 min – first results averaged for 3 min Recorded results are averaged for interval time 1÷4 min–...
Page 17
• The example of Data Socket Reader is available in the Program Menu Folder (SENSOR Electronic\Examples). • The built-in TCP/IP connection enables to communicate between different computers by the networks. TCP/IP routes data from server (AirDistSys 5000 program) to client. select ‘ ’...
Page 18
AirDistSys 5000 18 – Operator’s Manual • The frequency of data transfer for TCP connection is specified by the Interval Time. • The data transferred by TCP server are separated by TAB delimiters. The data string can be column headers or the results depending on setting the TCP connection.