Stand-alone test
26. Stand-alone test
The K8039 consists of 2 internal parts: a low-voltage part taking care of the DMX decoding and a high-
voltage part controlling the lamp. You can test the latter part with the self-testing function
Make sure the PCB is not live!
Close the "mode" jumper, JP2 by means of a shunt.
Set the DMX address to 0, i.e. all switches to "OFF".
Connect a light bulb (min 60W) with the output (LAMP OUT).
Switch on the K8039 (AC IN)
AC POWER
ADDRESS 0
The light bulb should slowly fade in and out.
Remove the power and shunt JP2.
13