UNIT
Fig. 16—Recommended Condensate Trap
PRIMARY TRAP REQUIRED
(USE FACTORY KIT OR
FIELD-SUPPLIED TRAP)
Fig. 18—Condensate Drain
Refer to outdoor unit Installation Instructions for system start-up instructions and refrigerant charging method details.
CAUTION: Never operate unit without a filter. Damage to blower motor or coil may result. FA4A units are not shipped
with filters. Factory authorized filter kits must be used when locating the filter inside the unit. For those applications where
access to an internal filter is impractical, a field-supplied filter must be installed in the return duct system.
To continue high performance and minimize possible equipment failure, it is essential that periodic maintenance be performed on this equipment.
Consult your local dealer as to the proper frequency of maintenance and the availability of a maintenance contract.
The ability to properly perform maintenance on this equipment requires certain mechanical skills and tools. If you do not possess these, contact
your dealer for maintenance. The only consumer service recommended or required is filter replacement or cleaning on a monthly basis.
"
1
2
4
"
1
2
4
FILTER
ACCESS
PANEL
SECONDARY DRAIN REQUIRED
(USE FACTORY KIT OR
FIELD-SUPPLIED TRAP)

CARE AND MAINTENANCE

A95321
Fig. 17—Insufficient Condensate Trap
WIRE
NUT
CONVERSION KIT
TRANSFORMER
TO
BLOWER
MOTOR
A99040
Fig. 19—Wiring Layout of Electronic Air Cleaner to Fan Coil
START-UP
—11—
DO NOT USE SHALLOW RUNNING TRAPS!
CES0130003-01
CONTROL BOARD
FAN RELAY
NO
NC
230VAC
COM
SPT
NO NC
208/230VAC
COM
24VAC
COM
TO EAC
A95320
R
G T C
COM
208/
230
FROM MOLEX
PLUG AND
TRANSFORMER
(IN UNIT)
A98626