4 PSU Connections
Connect photocell following output/telemetry if required into 'Fast Connect' wiring terminal.
Photocell following contact - White & Yellow wires
Volt free output. Non polarity sensitive.
Terminal 1 – white wire
Terminal 2 – Yellow wire
Telemetry input - Orange & Purple wires
Volt free/dry contact or TTL input
Terminal 3 – Orange wire
Terminal 4 – Purple wire
Automotive blade
output fuse
Cat5
Connector
Illuminator
Outputs 1+ 2
5 Connect PSU to mains
CAUTION: Ensure cable glands and PSU lid are water tight by tightening the fixings
Golden Rules
Ensure PSU lid orientation has warning label in line
with glands (see PSU diagram, right)
Ensure PSU is fully water tight
UK / Europe Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
High quality IP66
aluminium enclosure
White-Light LED
status indicators
Image featuring PSU-VAR-50W-2 (medium)
Slowblow
input fuse
Mains Input
'Fast-Connect'
wiring terminal:
inc. telemetry input
and photocell
following output
Glands x 5
!
www.rayteccctv.com
3