Download Print this page

Connection And Operation - Real-El AR-01 User Manual

Automatic network load controller

Advertisement

ENG
AR-01
User's Manual

4. CONNECTION AND OPERATION

Attention! The device must operate in the power supply network protected by an automatic
circuit breaker with the interrupting current not more than 16 А.
• Plug АNLС's power cord  into a standard socket of the home power supply system 230 V/50 Hz
(see the tentative connection diagram in Fig. 2). Indicators  and  active.
• Connect one of household electric appliances to the second socket  the operation of which is
uncritical to the short-time power supply failures (for example, electric water heater, electric con-
vector, floor heating electrical system etc.).
• Connect an electrical device to the "Priority" socket , the operation of which is required at the
moment and the power supply failure to which is inadmissible (for example, automatic washing
machine and dishwashing machine, electric pump of the water supply system, electric kettle, mic-
rowave oven, hair dryer etc.).
• If a device connected to the "Priority" socket  consumes more than 100 W, the power supply to
the second socket  is disconnected automatically. At that, the indicator  is not active. The power
supply to the second socket is recommenced automatically after 2 seconds after power reduction
consumed by a device plugged in the "Priority" socket below 100 W (sleep mode, timer mode etc.).
When the device connected to the "Priority" socket starts to operate at full capacity, the cycle recurs
once again.
• Example of АNLС operation is given in Fig. 2. A washing machine plugged in the "Priority" socket
is preset in the timer mode. While the timer of the washing machine does not start the washing mode,
the water heater plugged in the second socket will continue to operate. As soon as the washing
machine starts to operate, the second socket will be disconnected until the washing process is over
(when the second socket is disconnected, indicator  is not active).
~230 V
Mains
socket
АNLС
Washing machine
Boiler
Fig. 2. Tentative connection diagram
3
Technical support: www.real-el.com

Advertisement

loading