Kenwood RD-DV5-S Service Manual page 13

Micro hifi component system
Table of Contents

Advertisement

Low reflection disc
Step No.
Setting Method
Step 1
Test mode STOP state
Step 2
Press the SKIP DOWN(4) button six times. MANUAL adjustment menu
Step 3
Press once the MD PLAY button.
Step 4
Press once the SKIP DOWN(4) button.
Step 5
Press once the SKIP DOWN(4) button.
Step 6
Press once the SKIP DOWN(4) button.
Step 7
Press once the SKIP DOWN(4) button.
Step 8
Press once the SKIP DOWN(4) button.
Step 9
Press once the SKIP DOWN(4) button.
Step 10
Press once the SKIP DOWN(4) button.
Step 11
Press once the SKIP DOWN(4) button.
Step 12
Press once the SKIP DOWN(4) button.
Step 13
Press once the SKIP DOWN(4) button.
Step 14
Press once the SKIP DOWN(4) button.
Step 15
Press once the SKIP DOWN(4) button.
If the MD STOP button is pressed twice while the MANUAL adjustment menu is displayed, the state is changed to the TEST mode
STOP state.
8. TEST-PLAY mode
Step No.
Setting Method
Step 1
Test mode STOP state
Step 2
Press once the SKIP UP(¢)button.
Press MD PLAY button.
Step 3
Press the STOP button.
Step 4
Press
once the MD PLAY button.
Continuous playback (groove section)
Press once the MD STOP button.
Step 5
If the MD STOP button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
If the MD PLAY button is pressed while the TEST-PLAY menu is displayed, continuous playback is started from the current pickup position.
: Adress,
: Error late
9. TEST-REC mode
Setting Method
Step No.
Step 1
Test mode STOP state
Step 2
Press the
SKIP UP(¢)button twice.
Press MD PLAY button.
Step 3
Press the STOP button.
Step 4
Press
once the MD PLAY button.
Continuous playback
(groove section)
Step 5
Press once the MD STOP button.
If the MD STOP button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
If the MD PLAY button is pressed while the TEST-REC menu is displayed, continuous record is started from the current pickup position.
If
the (¡) or (1) button in remote controller is pressed in TEST-REC mode and continuous record mode,
the laser record power changes.
(Servo gain changes also according to the record power.)
: Adress,
: Laser power cord
10. EJECT mode
Step No.
Setting Method
Step 1
Test mode STOP state
Step 2
Test mode
EJECT
Step 3
Press SKIP UP(¢) button.
Step 4
Press STOP button.
: Measurement value,
CIRCUIT DESCRIPTION
Initial setting → Temperature measuring mode
Laser ON
Innermost periphery move → Tracking ATT (E signal) setting
Tracking ATT (F signal) setting
Indication of tracking EFMIO measurement (pit section)
Focus ATT (A signal) setting
Focus ATT (B signal) setting
Outside periphery move → Track closs setting
Tracking ATT (E signal) setting
Tracking ATT (F signal) setting
Indication of tracking EFMIO measurement (groove section)
Focus ATT (A signal) setting
Focus ATT (B signal) setting
During search the search output is set to "H", and it is
returned to "L" when continuous playback is started.
(Address + C1 error indication)
TEST-PLAY menu
During search the search output is set to "H", and it is
returned on "L" when continuous playback is started. (Address +
C1 error indication)
TEST-REC menu
state
Eject of MD disc
Temperature standard value setting.
: Setting value.
RD-DV5-S/DV7-L/DV5MD-S
Remarks
Remarks
Remarks
Remarks
Display
[ t s m
e
]
[ _ M N U _ A J S T _ ]
[ T M P : _
_ _ _ ]
[ L O N : _ _ _ _ _ _ ]
[ P E G :
]
[ P F G :
]
[ P M I :
_ _ _ ]
[ L A g :
]
[ L B g :
]
[ G C G :
]
[ G E G :
]
[ G F G :
]
[ G M I :
_ _ _ ]
[ L A G :
]
[ L B G :
]
Display
[ t s m
e
]
[ T E S T _ P L A Y _ ]
[a
c
]
[ T E S T _ P L A Y _ ]
[ T E S T _ P L A Y _ ]
Display
[ t s m
e
]
[ T E S T _ R E C _ _ ]
[ a
p w
]
[ T E S T _ R E C _ _ ]
[ a
p w
]
[ T E S T _ R E C _ _ ]
Display
[ _ _ E J E C T _ _ _ ]
[ TEMP
]
[ _ _ EJECT _ _ _ _ ]
13