READJUSTMENTS, ALTERATIONS, AND REPAIRS ........13 CLEANING AND MAINTENANCE ............. 14 STORAGE: ....................15 HOW TO STORE DEVICE:................. 15 TROUBLESHOOTING ................15 RECOMMENDED PLACEMENT AREAS............. 17 BEFORE OPERATING, PLEASE READ THIS USER’S MANUAL CAREFULLY AND BE CLEAR ABOUT THE INSTRUCTIONS. www.accumed.com...
The AP212 has 6 main opera�on modes with varia�ons within each main mode, totaling 16 modes to choose from. The main modes include: Mode 1 Massage (Varia�ons I, II, III), Mode 2 Acupuncture (Varia�ons I, II, III),...
Page 4
BE AWARE OF THE FOLLOWING 1) Consult with your physician before using this device. The simula�on with the device may: a. Cause lethal rhythm disturbances to the heart in suscep�ble individuals b. Disrupt the healing process a�er a recent surgical procedure. www.accumed.com...
Page 5
3) The charger supplied by the manufacturer must in compliance with IEC/EN 60601-1, the use of unauthorized chargers can impair the safety or damage the device. 4) The ba�ery needs to be charged for up to 10 hours before the first use. www.accumed.com...
-Timer: 10~60 minutes -Strength level adjustment: 20 levels -Charger: Input: 100-240V 50/60Hz 0.18A Max; Output: 1A; Class II, not applied part, not suitable for use in the presence of a flammable gases, with oxygen or nitrous oxide, or for con�nuous opera�on. www.accumed.com...
1500mm (59”) long Electrode cable INCLUDED IN THIS PACKAGE: * 1 Controller * 2 Pairs of electrodes [510(k) cleared] * 2 Output electrode cables * 1 Plas�c holder * 1 USB cable * 1 Charger * 1 User’s manual www.accumed.com...
Page 8
5) AB Bu�on OPERATE DEVICE 1. The AP212 unit needs to be charged for up to 10 hours before the ini�al use. 2. Make sure the power switch of the device is in the OFF posi�on. 3. Connect a pair of electrode pads to one lead wire by snapping them on.
2. Intensity: The intensity should be gradually increased un�l you reach the highest se�ng before it becomes uncomfortable. NOTE: The AP212 unit is safe. The output intensity is only increased by pushing the + key. Even if the intensity is increased to the maximum, it is within the safe range, but may feel uncomfortable.
Page 10
6) EAR: Very subtle, for extremely sensi�ve areas or people with sensi�vity to pulse sensa�ons. (like pulling on your ear lobe). NOTE: Start from the lowest intensity, and then gradually adjust to a comfortable level on a scale from 1 to 20. www.accumed.com...
(See Figure 2). 2. Intensity: The intensity can be gradually increased by one point. Always stay below the point of discomfort. Figure 2: Opposed Mode (Not recommended) www.accumed.com...
Page 12
2. Do not use the electrode pads on different people. Skin reac�on or cross contamina�on may occur. 3. Always turn off device before removing or reposi�oning the electrodes. 4. Wash skin thoroughly, and then dry it before applying the electrodes. www.accumed.com...
2. The manufacturer is only responsible for the safety and performance of AP212 when readjustments, altera�ons, and repairs are carried out by authorized individuals and when the AP212 is used in accordance with the user instruc�ons. 3. Qualified technicians who are familiar with the technical features of the device have been provided with circuit diagrams, PCB drawings, component lists, and se�ng instruc�ons by the manufacturer.
In this case, moisten the surface of the pads with water and wipe away the dirty por�on. This will allow a temporary restora�on of the adhesiveness. However, too much water will result in loss of the adhesiveness. www.accumed.com...
• Check if the ba�ery is low and needs to be recharged. • If the unit was previously used, switch the power to OFF first, then back to ON. 2. S�mula�on is weak or nonexistent: • Check that the electrode pads are firmly a�ached to skin. www.accumed.com...
Page 16
• This is normal. Different areas of your body will react differently. • Make sure the pads are s�cky and are making good contact. 6. Power cut off during use: • Check if ba�ery is low and charge if necessary. • Check that cord is intact and is not broken. www.accumed.com...
Mode 5 or 6 for 10-20 minutes; twice or 3 �mes a day. *Apply the electrodes to the pain • Pain in Back area. Avoid working in the same posi�on in the ini�al phase and change the posi�on at �mes. www.accumed.com...
Page 18
20 minutes; twice or 3 �mes a day. Figure 7 Mode 4 for 10-20 minutes, and Mode 6 for 10-20 minutes; twice or 3 �mes a day. * Do not use this device directly on the pain area or area of injury. Figure 8 www.accumed.com...
Page 19
NOTE: The charts below are merely a sugges�on for how to place the electrodes, what Mode to choose and how long to s�mulate, only a�er the user has gone through the star�ng procedure (above) and is familiar with the device. Mode 1 for 10-20 minutes, Mode 2 for 10-20 minutes, and Mode 6 for 10-20 minutes;...
Page 20
NOTE: The images below are mere sugges�ons on where to place the electrodes, but only a�er the user has gone through the star�ng procedure, this en�re user manual, and is familiar with the device. Targeted muscle SHOULDERS BACK BUTTOCKS ABDOMEN ARMS LEGS FEET...
Page 22
To contact AccuMed support, please do one of the following: • Visit h�p://accumed.com/contacts/ and use the email form • Call AccuMed Support at 1(713) 904-1955 support@accumed.com • Email AccuMed Customer Support www.AccuMed.com For more informa�on please visit Manufactured for: AccuMed Biotech...