AccuMed AP212 User Manual

Mini electronic pulse stimulator
Hide thumbs Also See for AP212:

Advertisement

Quick Links

USER MANUAL

AP212 Mini Electronic Pulse S�mulator
V2.0.1
Revised: March 10, 2017
www.AccuMed.com

Advertisement

Table of Contents
loading

Summary of Contents for AccuMed AP212

  • Page 1: User Manual

    USER MANUAL AP212 Mini Electronic Pulse S�mulator V2.0.1 Revised: March 10, 2017 www.AccuMed.com...
  • Page 2: Table Of Contents

    READJUSTMENTS, ALTERATIONS, AND REPAIRS ........13 CLEANING AND MAINTENANCE ............. 14 STORAGE: ....................15 HOW TO STORE DEVICE:................. 15 TROUBLESHOOTING ................15 RECOMMENDED PLACEMENT AREAS............. 17 BEFORE OPERATING, PLEASE READ THIS USER’S MANUAL CAREFULLY AND BE CLEAR ABOUT THE INSTRUCTIONS. www.accumed.com...
  • Page 3: Introduction

    The AP212 has 6 main opera�on modes with varia�ons within each main mode, totaling 16 modes to choose from. The main modes include: Mode 1 Massage (Varia�ons I, II, III), Mode 2 Acupuncture (Varia�ons I, II, III),...
  • Page 4 BE AWARE OF THE FOLLOWING 1) Consult with your physician before using this device. The simula�on with the device may: a. Cause lethal rhythm disturbances to the heart in suscep�ble individuals b. Disrupt the healing process a�er a recent surgical procedure. www.accumed.com...
  • Page 5 3) The charger supplied by the manufacturer must in compliance with IEC/EN 60601-1, the use of unauthorized chargers can impair the safety or damage the device. 4) The ba�ery needs to be charged for up to 10 hours before the first use. www.accumed.com...
  • Page 6: Specifications And Essential Performance

    -Timer: 10~60 minutes -Strength level adjustment: 20 levels -Charger: Input: 100-240V 50/60Hz 0.18A Max; Output: 1A; Class II, not applied part, not suitable for use in the presence of a flammable gases, with oxygen or nitrous oxide, or for con�nuous opera�on. www.accumed.com...
  • Page 7: Features

    1500mm (59”) long Electrode cable INCLUDED IN THIS PACKAGE: * 1 Controller * 2 Pairs of electrodes [510(k) cleared] * 2 Output electrode cables * 1 Plas�c holder * 1 USB cable * 1 Charger * 1 User’s manual www.accumed.com...
  • Page 8 5) AB Bu�on OPERATE DEVICE 1. The AP212 unit needs to be charged for up to 10 hours before the ini�al use. 2. Make sure the power switch of the device is in the OFF posi�on. 3. Connect a pair of electrode pads to one lead wire by snapping them on.
  • Page 9: Two Key Points For Operations

    2. Intensity: The intensity should be gradually increased un�l you reach the highest se�ng before it becomes uncomfortable. NOTE: The AP212 unit is safe. The output intensity is only increased by pushing the + key. Even if the intensity is increased to the maximum, it is within the safe range, but may feel uncomfortable.
  • Page 10 6) EAR: Very subtle, for extremely sensi�ve areas or people with sensi�vity to pulse sensa�ons. (like pulling on your ear lobe). NOTE: Start from the lowest intensity, and then gradually adjust to a comfortable level on a scale from 1 to 20. www.accumed.com...
  • Page 11: Recommended Practices

    (See Figure 2). 2. Intensity: The intensity can be gradually increased by one point. Always stay below the point of discomfort. Figure 2: Opposed Mode (Not recommended) www.accumed.com...
  • Page 12 2. Do not use the electrode pads on different people. Skin reac�on or cross contamina�on may occur. 3. Always turn off device before removing or reposi�oning the electrodes. 4. Wash skin thoroughly, and then dry it before applying the electrodes. www.accumed.com...
  • Page 13: Readjustments, Alterations, And Repairs

    2. The manufacturer is only responsible for the safety and performance of AP212 when readjustments, altera�ons, and repairs are carried out by authorized individuals and when the AP212 is used in accordance with the user instruc�ons. 3. Qualified technicians who are familiar with the technical features of the device have been provided with circuit diagrams, PCB drawings, component lists, and se�ng instruc�ons by the manufacturer.
  • Page 14: Cleaning And Maintenance

    In this case, moisten the surface of the pads with water and wipe away the dirty por�on. This will allow a temporary restora�on of the adhesiveness. However, too much water will result in loss of the adhesiveness. www.accumed.com...
  • Page 15: Storage

    • Check if the ba�ery is low and needs to be recharged. • If the unit was previously used, switch the power to OFF first, then back to ON. 2. S�mula�on is weak or nonexistent: • Check that the electrode pads are firmly a�ached to skin. www.accumed.com...
  • Page 16 • This is normal. Different areas of your body will react differently. • Make sure the pads are s�cky and are making good contact. 6. Power cut off during use: • Check if ba�ery is low and charge if necessary. • Check that cord is intact and is not broken. www.accumed.com...
  • Page 17: Recommended Placement Areas

    Mode 5 or 6 for 10-20 minutes; twice or 3 �mes a day. *Apply the electrodes to the pain • Pain in Back area. Avoid working in the same posi�on in the ini�al phase and change the posi�on at �mes. www.accumed.com...
  • Page 18 20 minutes; twice or 3 �mes a day. Figure 7 Mode 4 for 10-20 minutes, and Mode 6 for 10-20 minutes; twice or 3 �mes a day. * Do not use this device directly on the pain area or area of injury. Figure 8 www.accumed.com...
  • Page 19 NOTE: The charts below are merely a sugges�on for how to place the electrodes, what Mode to choose and how long to s�mulate, only a�er the user has gone through the star�ng procedure (above) and is familiar with the device. Mode 1 for 10-20 minutes, Mode 2 for 10-20 minutes, and Mode 6 for 10-20 minutes;...
  • Page 20 NOTE: The images below are mere sugges�ons on where to place the electrodes, but only a�er the user has gone through the star�ng procedure, this en�re user manual, and is familiar with the device. Targeted muscle SHOULDERS BACK BUTTOCKS ABDOMEN ARMS LEGS FEET...
  • Page 22 To contact AccuMed support, please do one of the following: • Visit h�p://accumed.com/contacts/ and use the email form • Call AccuMed Support at 1(713) 904-1955 support@accumed.com • Email AccuMed Customer Support www.AccuMed.com For more informa�on please visit Manufactured for: AccuMed Biotech...