Page 2
European Union Declarations of Conformity LG-Ericsson Co., Ltd. declares that the equipment specified in this document, which bears the “CE” mark, conforms to the European Union Radio and Telecommunications Terminal Equipment Directive (R&TTE...
Page 3
SBG-1000 Quick Start Guide 3. Privacy: This multi-line telephone system (MLTS) implements security and encryption technologies appropriate for DECT however, privacy of communications may not be ensured when using this telephone. 4. RF Exposure Statement: This equipment complies with FCC/IC RF radiation exposure limits set forth for an uncontrolled environment.
Quick Start Guide 1. SBG-1000 Network Connection Diagram SBG-1000 (Smart Business Gateway-1000) SBG-1000 is all-in-one multi-service communication solution via single Internet connection for small businesses. The following figure shows the components that make up the SBG-1000 system. Figure 1. Network Connection Diagram...
SBG-1000 Quick Start Guide Unpacking Open the box and verify the items shown in the following figure are included: Figure 2.1. SBG-1000 Carton Contents...
3. Insert 3 included screws into the 3 anchor plugs. 4. Install the SBG-1000 system to the wall mount bracket. Figure 2.2.1. Wall Mounting Note: Basically, LG-ERICSSON recommends the wall mounting installation for better wireless characteristics. 2.2.2. Wiring Arrangement Figure 2.2.2. Wiring Arrangement...
4.1 Connection for AC/DC adapter 1. Open the side cover. 2. Connect the plug of AC/DC adapter on the right side of the SBG-1000 system. 3. Close the side cover and insert SBG-1000 system to the wall mount bracket. 4. Connect the plug of power cord to a wall outlet.
FUNCTION RJ45 4,5,7,8 Reserved Transmit Data Transmit Data Receive Data Receive Data Note: SBG-1000 has 4 PoE ports for LAN1 ~ LAN4. (Maximum 20W). 4.2.1.2 Pin Assignment for Ethernet (WAN) WAN port CONNECTOR PIN NUMBER SIGNAL NAME FUNCTION RJ45 DA_P...
Page 12
PSTN back-up functions can be supported using ONLY one of following daughter board types assembled from the factory. Daughter board types Resources Remark CIU1 installed in SBG-1000 CO 1 port CO Interface Unit CIU2 installed in SBG-1000 CO 2 ports...
Page 13
SBG-1000 Quick Start Guide 4.2.2 Port definition – Left side The following figure shows for USB connection. Figure 4.2.2.1. Connection for USB USB port CONNECTOR PIN NUMBER SIGNAL NAME USB Type A 4 3 2 1 VBUS (+5V) Example for USB port...
Reset to defaults Database clear Refer to CD manual for more detail Note: . WPS button is used for activating wireless device connections. . Reset to defaults button is used for clearing SBG-1000‟s database only when pressed more than 5 seconds.
SBG-1000 Quick Start Guide 5.2. LED Icons The following figure shows for the Icons on the top of SBG-1000. Figure 5.2. LED Icons Icons Functions Remark On – Connected Power Power Connection Off or Blink – Abnormal or not connected (Blue) On –...
SBG-1000 Quick Start Guide 5.3. LEDs The following figure shows for LED functions. Figure 5.3. LEDs 5.3.1. LEDs for Ethernet (WAN) LED Indication (WAN port) DESCRIPTION Activity Status LED – Blink : Activity, ON : Idle Orange color Link Status LED – ON : Link OK, OFF : No Link Green color 5.3.2.
Figure 6.1 Welcome to SBG-1000 Installation Wizard To start the installation wizard, perform the following: Select the desired language and click „Next‟ to continue.
Page 18
The first step is a test of the Ethernet connection. Figure 6.3 Test Ethernet Link This step may fail if SBG-1000 cannot detect your Ethernet link (for example, if the cable is unplugged). In this case, the screen changes to the following.
Page 19
The next step is an analysis of your Internet connection. Figure 6.5 Analyze Internet Connection Type This step may fail if SBG-1000 is unable to detect your Internet connection type. Figure 6.6 Analyze Internet Connection Type – Failure In this case, you can manually set the Internet connection type, by clicking the corresponding button. The following screen appears.
Page 20
Figure 6.9 Setup Internet Connection You may have forgotten your login details, issued by your ISP. SBG-1000 saves the username and password of the PPPoE connection to the ISP, even if it is restored to the factory default settings. When restoring the connection with the installation wizard, SBG-1000 will offer your old login details.
Page 21
SBG-1000 Quick Start Guide 6.4 Step 4: Test Service Provider Connection This step tests the connectivity to your ISP. Figure 6.10 Test Service Provider Connection 6.5 Step 5: Test Internet Connection This step tests the connectivity to the Internet. Figure 6.11 Test Internet Connection 6.6 Step 6: Wireless Setup...
Page 22
Quick Start Guide SBG-1000 assigns a default name for its wireless network, which you may later change. Select the wireless security level. The default “Medium” level secures your network by requiring users to provide a password in order to connect.
Page 23
SBG-1000 Quick Start Guide Connections‟ screen under the „System‟ tab, where it can be edited or deleted such as any other network connection. Figure 6.15 Network Connections Note: In order to delete this connection, you must first remove it from under the LAN bridge.
SBG-1000 Quick Start Guide Problem Cause/Symptom Solution Check the AC Power source. AC Power Fail Check the Inlet and adapter connection. Replace AC/DC adapter with a good one. System power failure Power On/Off Icon Check DC Output voltage and DC/DC.
Page 25
RSS‐GEN Section 7.1.5. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. ...
Page 27
Rapport d'exposition de rayonnement d'IC rf : Cet équipement est conforme aux limites d'exposition de rayonnement d'IC rf déterminées pour un environnement non contrôlé. Ce dispositif et son antenne ne doivent pas n'être coïmplantés ou opération en même temps qu'aucune autre antenne ou émetteur.
Page 28
FCC RF Radiation Exposure Statement The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operation in conjunction with any other antenna or transmitter.
Need help?
Do you have a question about the SBG-1000 and is the answer not in the manual?
Questions and answers