CHARDER MEDICAL MS 3910 User Manual

Medical scale

Advertisement

Quick Links

MS 3910 (DP3700)
Medical Scale

USER MANUAL

Please keep the instruction manual at hand all the time for future reference.
- 0 -

Advertisement

Table of Contents
loading

Summary of Contents for CHARDER MEDICAL MS 3910

  • Page 1: User Manual

    MS 3910 (DP3700) Medical Scale USER MANUAL Please keep the instruction manual at hand all the time for future reference. - 0 -...
  • Page 2: Table Of Contents

    USING INTERNAL SETTING ..............21 STORING AND RE-CALLING PRE-TARE WEIGHT......22 PRINTING FUNCTION ................25 INSTRUCTION FOR CHARGING AND CONNECTING ......27 INSTRUCTION FOR REPLACING BATTERIES ........28 MS 3910 ASSEMBLY................31 SSEMBLING HEIGHT ROD HM201M/201D/210D ON WIDE COLUMN....................32 ASSEMBLING TP21xx SERIES THERMO PRINTER ON SCALE..34 ERROR MESSAGE ...................35...
  • Page 3: Preface

    This device is designed for use indoors. Observe the permissible ambient temperatures for use The device meets the requirements for electromagnetic compatibility. Do not exceed the maximum values specified in the applicable standards. If you have any question, contact your local CHARDER MEDICAL service partner.
  • Page 4: Enviromental

    The regularity of these checks is dependent on the level of use and the state of the scale. If any inaccuracies occur, please contact your local dealer or CHARDER MEDICAL service partner. WEIGHING OPERATION Before reading detailed instructions on how to use all the weighing...
  • Page 5: Warranty-Liability

    Please retain your receipt as proof of purchase. Should your scale require servicing, please contact your dealer or CHARDER MEDICAL Customer Service. No responsibility shall be accepted for damage caused through any of the following reasons: Unsuitable or improper storage or use,...
  • Page 6: Disposing Of The Scale

    DISPOSING OF THE SCALE This product is not to be treated as regular household waste, but should be handed in to an electrical/electronic equipment recycling centre. You can obtain further details from your local council, your municipal waste disposal company or the firm which you purchased the product.
  • Page 7: Explanation Of The Graphic Symbols

    EXPLANATION OF THE GRAPHIC SYMBOLS SN-T13000001 Designation of the serial number of every device, applied at the device. (Number as an example) “Please note the accompanying documents“ or “Observe operating instructions” Identification of manufacturer of medical product including address Charder Electronic Co., Ltd. No.103, Guozhong Rd., Dali Dist., Taichung City 412, Taiwan (R.O.C.) Type B applied part...
  • Page 8 Transport and storage temperature limit indicating the upper and the +60°C lower limit (Transport and storage temperature on packaging) -20°C...
  • Page 9: Emc Guidance And Manufacturer's Declaration

    EMC guidance and manufacturer's declaration Guidance and manufacturer’s declaration-electromagnetic emissions The MEDICAL SCALE MS3910 is intended for use in the electromagnetic environment specified below. The customer or the user of the MEDICAL SCALE MS3910 should assure that it is used in such an environment. Electromagnetic Emission test Compliance...
  • Page 10 Electrostatic ± 6 kV contact ± 6 kV contact Floors should be wood, discharge(ESD) ± 8 kV air ± 8 kV air concrete or ceramic tile. IEC 61000-4-2 If floors are covered with synthetic material, the relative humidity should be at least 30% Electrical fast ±...
  • Page 11 Guidance and manufacturer’s declaration-electromagnetic immunity The MEDICAL SCALE MS3910 is intended for use in the electromagnetic environment specified below. The customer or the user of the MEDICAL SCALE MS3910 should assure that is used in such and environment. IEC 60601 test Compliance Electromagnetic Immunity test...
  • Page 12 NOTE1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
  • Page 13: Specification

    SPECIFICATION Model MS 3910 Capacity 300kg x 0.1kg ±0.15kg Accuracy OIML Approval Class III Weight Unit LCD Display 1.0 inch LCD display with 5 and 1/2 digits Pole Height: 800 mm Dimension Platform size: 340 x 450 mm ON/OFF, ZERO, PRINT, BMI, HOLD, PRE-...
  • Page 14: Power Adaptor Standards

    POWER ADAPTOR STANDARDS CAUTION: The device is only compatible with restricted power adaptors in dashed block below.
  • Page 15: Panel

    Standard Accessories Item Spec. Accessories Qty. RS232 cable WR-8159 12V Adaptor MS3910 user IN-1178 manual Screw (Optional: for M4*20 wheel version) PANEL...
  • Page 16: Key Function

    KEY FUNCTION Description ON/OFF Turn ON/OFF the scale PRINT Data transmission via interface (Print-out the results) To determine Body Mass Index To determine stable weighing value in case of HOLD unstable weight. To reset the display to 0.0kg display / Zero the scale ZERO (±2% of full capacity) M1-5...
  • Page 17: Lcd Symbol Description

    LCD SYMBOL DESCRIPTION Definitions Stable symbol: To indicate that the weight is stable. Minor weight: Weight under zero. Zero symbols: Weight is at zero point. Low battery: Battery need to charge or replaced.
  • Page 18: Time Setting

    TIME SETTING Long press HOLD key for 3 seconds to enter the TIME SETTING mode, beginning with the top row, with the flashing digit. Press HOLD key after successful change to move to next step. EX: To input Dec 25, 2008, 8:00am. Enter year using keys from 0~9.
  • Page 19: Using Hold Function

    If a person is heavier than the scale capacity, the display will show the „Err” prompt (= overload). USING HOLD FUNCTION MS 3910 is provided with the integrated hold function to determine the average weight. It enables people to be weighed accurately although they are not still on the scale platform.
  • Page 20: Using Bmi Feature

    BMI value. At this stage, the weight and height can be changed, and the MS 3910 will automatically calculate the BMI value according to the changed weight and height. HOLD feature can also be used if the weight is unstable.
  • Page 21: Using Tare Function

    USING TARE FUNCTION Tare allows the user to zero the instrument to deduct the weight of a container/ clothes from the reading of the instrument, thus giving the true weight of the product/ person being tested. Place the object need to be tare on the tread platform. Press “TARE”...
  • Page 22: Using Internal Setting

    USING INTERNAL SETTING Switch ON the scale and long press [ZERO] key for 3 seconds, first “SETUP” and then “A.OFF” will display successively. AUTO-OFF TIME SETUP This enables operator to select the auto turn OFF time of the device. Auto off time: 120 sec/180 sec/240 sec/300 sec/off **Please Press ‘Tare’...
  • Page 23: Storing And Re-Calling Pre-Tare Weight

    STORING AND RE-CALLING PRE-TARE WEIGHT MS 3910 can store 5 sets of pre-tare values, and there are two methods to store pre-tare value – Using Dead Weight or Enter weight using 0~9 keys: A. Using Dead Weight: DESCRIPTION EXAMPLE Press M1-5 key after loading the weight on the platform;...
  • Page 24 Enter pre-tare weight using 0~9 keys. For example- 5kg. Press ENTER key to confirm the pre-tare weight; the display will show the minus sign on left of the pre-tare weight value. Press M1-5 key; the blinking m sign will appear on the display. Press numeral key 1 ~ 5 to assign the position to pre-tare weight.
  • Page 25 C. RECALL PRE-TARE VALUE DESCRIPTION EXAMPLE Long press PRE-TARE key for 3 seconds; the display will show pre-tare value- m1 firstly. The pre-tare value will blink. Press numeral key 1 ~ 5 to choose pre-tare value Press ENTER key to confirm the pre-tare weight;...
  • Page 26: Printing Function

    PRINTING FUNCTION Weight, BMI and Height results can be printed for records using RS232 interface cable (included in accessory kit). After weighing and calculating BMI simply press PRINT key to print out the results. The format presented below is the standard format of results print- out and cannot be changed.
  • Page 27 RS232 Pin out Connecting with PC 1. Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu → Programs → Accessories → Communication → Hyper Terminal. 2. New Connection Description Give new connection a name then click OK. 3. Select Your COM Port Click Connect to select your COM port.
  • Page 28: Instruction For Charging And Connecting

    INSTRUCTION FOR CHARGING AND CONNECTING prompt displays on the LCD, please charge the scale with MS 3910 exclusive adaptor or replace the batteries. Locate adaptor plug on the right side of indicator. RS232 Connector AC Jack Connector CAUTION: Always connect the AC adaptor with the indicator before connecting to the mains power supply.
  • Page 29: Instruction For Replacing Batteries

    INSTRUCTION FOR REPLACING BATTERIES Open the battery housing cover Take out the battery housing...
  • Page 30 Rechargeable Battery and AA-size Battery Housing Rechargeable Battery Housing AA-size Battery Housing Make sure that all the batteries are properly placed...
  • Page 31 Place the battery housing back and make sure that the housing pin is connecting to the right point Place the housing back Close the battery housing cover...
  • Page 32: Ms 3910 Assembly

    MS 3910 ASSEMBLY 1. Assemble the column with the platform. 2. Tighten the four(4) screws of column through base.
  • Page 33: Ssembling Height Rod Hm201M/201D/210D On Wide Column

    SSEMBLING HEIGHT ROD HM201M/201D/210D ON WIDE COLUMN Step 1. Assemble two brackets on the column Item Name Quantity M5x0.8x11 round head screw Relief Bushing Bracket for HM-200D * Photo of display for reference only. Please refer to the actual product.
  • Page 34 HM201M is mechanical height rod which has same assembly procedure with HM200D/201D. Step 2. Fix HM200D/201D/201M on the bracket and tighten the screw. Item Name Quantity HM201M/HM201D/HM200D M5x10L flat head screw Fixing block M5x0.8x11 * Photo of display for reference only. Please refer to the actual product.
  • Page 35: Assembling Tp21Xx Series Thermo Printer On Scale

    ASSEMBLING TP21xx SERIES THERMO PRINTER ON SCALE Item Parts M5*15L head screw Screws for printer bracket Printer bracket...
  • Page 36: Error Message

    ERROR MESSAGE...
  • Page 37: Troubleshooting

    TROUBLESHOOTING Troubleshooting for defective modes: Original purchaser can enjoy the benefits under the effective Warranty against functional defects in material and workmanship subject to the terms and conditions listed in the yearly Warranty Program & Return Policy. Our warranty service program includes the following: 1.
  • Page 38 Unstable platform feet adjustments according to bubble level indication Incorrect position or other external objects within weighing area The weighing-scale is not put in a solid & firm ground area, such as carpet floor or lawn. 3. Connection failure for data transmission to PC or printer Wrong connection wires or faulty wires for transmission between the digital indicator &...
  • Page 39 Wrong welding of PVC wire Key buttons & control panel damaged or disconnected...
  • Page 41 Manufacturer’s Declaration of Conformity This product has been manufactured in accordance with the harmonized European standards, following the provisions of the below stated directives: 93/42/EEC amended 2007/47/EC Medical Device Directive 2014/31/EU Non-automatic Weighing Instruments Directive Please see separate document showing on sticker of device for above CE marking.

This manual is also suitable for: