UPDATING THE DISPLAY SOFTWARE
The software from time to time will be updated, this
maybe to add features or options. Beta Marine can
provide up to date files on request.
Before updating your software please read the
following instructions carefully and be aware that it is
extremely important that only a USB stick is used that only
has the required two Beta Marine files within and contains
no other data.
Note: Panel D is permanently live to the engine start
battery for engine stop/start. The panel power switch only
turns on or off the panel display screen. For your safety
please ensure that when requested the starter battery is
isolated from the panel.
Before proceeding with a software update the current
engine hours must be recorded. Please refer to CONFIG
MENU section of this manual.
To ensure you software is up to date please email:
spares@betamarine.co.uk or telephone: +44 (0)1452
723492.
SOFTWARE INSTALLATION
1. Switch off/isolate engine battery and remove the D
Panel from the vessels installation point but keep the
11-way plug connected.
Fig 2
If your software is not current and an update is required
Beta Marine will require visual proof of existing engine
hours before free issuing the new software.
Note: Due to the narrow recess and depth of the USB
connection socket it will be necessary to have a USB
connection extension lead available. Depending on cable
flexibility it may have to be supported with an appropriate
guide.
Fig 1
2. Remove the rubber grommet/bung from the rear of
the panel (Fig 2 & Fig 3).
Fig 3