SET TEMPO

There are multiple ways to set the tempo on the Quartz V2, you can do this by:
Turning the Temp/Save knob.
a)
b)
Tap one of footswitches*.
c)
Receive MIDI Clock from external MIDI device.
d)
Receive Metronome Tempo via the 1/8" Metronome Input.
*You need to ensure that the footswitch that you are using has the function "Tap Tempo" assigned to it. Please refer to the
FOOTSWITCH FUNCTIONS section.

CHANGE PRESET

There are multiple ways to change preset on the Quartz V2, you can do this by:
Turning the Preset/Edit knob.
a)
b)
Tap or Hold one of the footswitches*
c)
Receive MIDI Program Change message from external MIDI device.
*You need to ensure that the footswitch that you are using has the appropriate function assigned to it. Please refer to the
FOOTSWITCH FUNCTIONS section.

AUX JACKS

The Aux Jacks on the Quartz V2 are double purposed. Jacks 1, 2, and 3 can be either inputs, or outputs. Jack 4 is always an
output but it has the ability to be modified to support Diamond pedals.

TAP OUTPUTS

The four 1/4" jacks can be used as "Tap Outputs" to connect to the "Tap Inputs" of effects that do not have Midi. In the Global
Menu you can set each output to a different polarity to match the needs of the pedals you have. "Normally Open", Normally
Closed", "TRS" configuration used by most Strymon pedals, and a "DIG" option for the Strymon DIG. The number of times the
pedal pulses and its latch time (how long it stays engaged) can also be determined separately for each output.

LEAD/CABLE TYPES

To use a Tap Output you will need one of two leads. A 1/4 inch Stereo TRS (Tip, Ring, Sleeve) lead, or a standard 1/4 inch
Mono TS (Tip, Sleeve) lead.
- If you set Polarity to "Normally Open" or "Normally Closed", a standard 1/4 inch TS patch lead will do.
- If you set Polarity to "TRS" or "DIG" you will need a TRS lead

POLARITY

- "Normally Open" disconnects the Tip and Sleeve by default and then momentarily connects them together.
- "Normally Closed" connects the Tip and Sleeve by default and then momentarily disconnects them.
- "TRS" connects the Tip and Sleeve by default and then momentarily disconnects the Tip and Sleeve while
connecting the Tip and Ring.
- "DIG" connects the Tip and Ring by default and then momentarily connects all three Tip, Ring, and Sleeve together.