When you perform this task, follow the IRF physical interface restrictions and configuration guidelines in
the following sections:
IRF physical interface
Binding physical interfaces to IRF
To add physical interfaces to IRF ports:
Step
1.
Enter system view.
2.
Enter Ethernet interface view
or interface range view.
3.
Shut down the physical
interfaces.
4.
Return to system view.
5.
Enter IRF port view.
6.
Bind each physical interface
to the IRF port.
7.
Return to system view.
restrictions.
ports.
Command
system-view
Enter interface range view:
interface range { interface-type
interface-number [ to interface-type
interface-number ] } &<1-24>
Enter interface view:
interface interface-type
interface-number
shutdown
quit
irf-port member-id/port-number
port group interface interface-type
interface-number [ mode enhanced ]
quit
22
Remarks
N/A
To shut down a range of IRF
physical interfaces, enter
interface range view.
To shut down one IRF physical
interface, enter its interface
view.
CAUTION:
If you have connected two peer
IRF physical interfaces, shut down
both interfaces before assigning
them to their respective IRF ports.
Failure to do so might cause IRF
split.
If the system does not allow you
to shut down a physical
interface, follow the system
instruction to shut down its
remote peer interface.
N/A
N/A
By default, no physical interfaces
are bound to any IRF port.
Repeat this step to assign
multiple physical interfaces to
the IRF port.
You can bind a maximum of
eight physical interfaces to an
IRF port.
An IRF physical interface
operates in enhanced mode
after the IRF binding takes effect,
regardless of whether you have
specified the mode enhanced
keywords.
N/A