Graphic Equalizer Operation Check; Perfect Volume Operation Check; Dynamic Bass Operation Check; Sub-Picture Position - Hitachi 60DX10B Service Manual

Hp11; hp 12 chassis
Hide thumbs Also See for 60DX10B:
Table of Contents

Advertisement

(5) Check the EXT RGB CONT : 60 of V/C I
by using JIG R/C.
(6) White signal spec. amplitude 2.0Vpp (Sync.
0.6Vpp)
Adjustment procedure
(1) Observe P802 on the CPT P.W.B. and change
the PKL B of service mode by using jig R/C and
adjust so that the amplitude of the sub picture is
the same as that of the main picture.
(2) Similarly, observe P832 on the CPT P.W.B. and
change the PKL G of service mode by using jig
R/C and adjust so that the amplitude of the sub
picture is the same as that of the main picture.
(3) Similarly, observe P862 on the CPT P.W.B. and
change the PKL R of service mode by using jig
R/C and adjust so that amplitude of the sub
picture is the same as that of the main picture.
(4) Check the matching the white balance of the
sub picture with that of the main picture.
If it does not, return to step (1).
* Adjustment specification : ±1V
* Quality control specification: ±3V
* Wave form of P802, P832, P862 = Cathode.
(Sub picture levvel compared with main picture
level.)
1V
Main Picture
(White)
1V
Vertical
SAG
Sub Picture
Center Point
*
Perform this adjustment after the white balance
and sub-brightness adjustments of the main
picture are completed.
*
White balance 10800˚K -7 MPCD (color
coordinates : x=0.278, y=0.280)
*
Refer to the sub-brightness adjustment for
details of the gray scale of color bar signal.
C ADJ.
2
Sub Picture
(White)
2.15.3 SUB PICTURE POSITION ADJUSTMENT
Adjustment preparation
(1) Select the Circle Pattern signal on main picture.
(2) Video settings has to be at normal condition
Adjustment procedure
(1) Go to "PinP POSITION ADJ." mode.
(2) Adjust vertical position and Horizontal position.
Lower Line
Circle Pattern
NOTE: The micro-controller has an original data for the
PIP position for HP and VP, if the position needs
to be re-adjusted then do the procedure for this
adjustment, in case that the position of PIP is
between the spec. 5.5±0.5 and close to the
lower line of the circle pattern no need to adjust
only checking.
34
From Lower Line 5mm
Separation Tolerance
in the lower line
3
5
5
3