10.
SAFETY DEVICES
Protection form
Current fuse
(Near the terminal)
Circuit protection
Current fuse
(Main PC board)
Fan motor
Thermal protection
protection
program
Thermal protection program
(Compressor temp.)
Compressor
protection
Thermal protection program
(Discharge temp.)
High pressure
Pressure switch
protection
AOG18LFC
AOG24LFCC
250 V 20 A
250 V 5 A
250 V 15 A
250 V 20 A
250 V 3.15 A
250 V 5 A
OFF : 100 ± 15 °C
OFF : 100 ± 15 °C
ON : 95 ± 10 °C
ON : 95 ± 10 °C
OFF : 108 °C
�
ON : After 40 minutes
OFF : 110 °C
OFF : 110 °C
ON : After 7 minutes
ON : After 7 minutes
OFF : 4.2 ± 0.1 MPa
�
ON : 3.2 ± 0.15 MPa
- (02 - 20) -
Model
AOG30LFT
�
250 V 20 A
�
250 V 5 A
250 V 15 A
250 V 3.15 A
OFF : 150 ± 15 °C
ON : 120 ± 15 °C
OFF : 108 °C
ON : After 40 minutes
OFF : 110 °C
ON : After 7 minutes
OFF : 4.2 ± 0.1 MPa
ON : 3.2 ± 0.15 MPa