SpECIfICatIonS

MoDEl
InpUt VoltaGE
no.
RanGE (VDC)
IDC-360A-12
9 - 18
IDC-360B-12
20 - 35
IDC-360C-12
30 - 60
IDC-360D-12
60 - 120
IDC-360A-24
9 - 18
IDC-360B-24
20 - 35
IDC-360C-24
30 - 60
IDC-360D-24
60 - 120
IDC-360B-48
20 - 35
IDC-360C-48
30 - 60
no loaD CURREnt DRaW
InpUt to oUtpUt ISolatIon
oUtpUt RIpplE & noISE
pEaK EffICIEnCY
CoolInG
opERatInG tEMpERatURE
anD DE-RatInG
HUMIDItY, non-ConDEnSInG
pRotECtIonS
SafEtY anD EMC StanDaRDS
eMissiONs
iMMuNiTy
AuTOMOTiVe DireCTiVe
InpUt / oUtpUt ConnECtIonS
DIMEnSIonS (W x D x H)
WEIGHt
NOTe: specifications are subject to change without notice
Height: 83 mm
181
190.5
MaX InpUt
oUtpUt
CURREnt (a)
VoltaGE (VDC)
CURREnt (a)
<40
12.5
<30
12.5
<20
12.5
<10
12.5
<40
24.5
<30
24.5
<20
24.5
<10
24.5
<30
48.0
<20
48.0
< 25 mA
Yes. > 400V RMS
< 50 mV RMS
85%
By temperature controlled fan
-20 to +30oC / -4oF to 86oF
(De-rate linearly to zero at 70oC / 158oF)
Max 95%
Overload / short circuit on the output side;
Over voltage on the output side; Over voltage /
transients on the input side; Reverse polarity on
the input side; Over heating
EN55014-1
EN55014-2
UN Regulation ECE R10-4
Quick Connect ; Male, 6.3 mm /
1/4" flat blade
132.8 x 190.5 x 83 mm / 5.23 x 7.5 x 3.27 in
1.4 Kg / 3.1 lb
132.8
91
FRONT
SIDE
5
LEGEND
1. Input +
2. Input -
3. Output -
4. Output +
5. Chassis Ground
taBlE 1.
exTerNAL iNPuT siDe Fuse & WiriNg
oUtpUt
MoDEl
naME
IDC-360A-12, 24
30
IDC-360B-12, 24, 48
30
IDC-360C-12, 24, 48
30
IDC-360D-12, 24
30
15
taBlE 2.
15
exTerNAL OuTPuT siDe Fuse & WiriNg
15
MoDEl
15
naME
7.5
IDC-360A-12
7.5
IDC-360B-12
IDC-360C-12
IDC-360D-12
IDC-360A-24
IDC-360B-24
IDC-360C-24
IDC-360D-24
IDC-360B-48
IDC-360C-48
notES foR taBlE 1 anD 2:
a) Wire sizes shown are based on 90oC / 194oF wire temperature rating and
2% voltage drop over distance of 3' from battery or load for current =
Amp rating of the fuse.
b) For distances > 3', use thicker wires to limit voltage drop to <2% for
current = Amp rating of the fuse.
tERMInatIon of ConnECtInG WIRES:
c) Use 6.3mm / 1/4" "Quick Connect", Female mating terminal on the
connecting wiring. This type of terminal is available for maximum wire
size of AWG #10. When using wires thicker than AWG #10, you may
terminate the wire as follows:
• U se 6.3mm / 1/4" "Quick Connect" Female matting connector
(AWG #10 size)
• U se around 2" piece of AWG #10 wire and crimp the connector to one
end Solder / splice the other end of AWG #10 wire to wire the thicker wire
Use of short length of 2" of smaller AWG #10 wire will not increase voltage
drop appreciably.
6
1
2
3
4
91mm
6. Fan suction openings
7. Fan
}
At the back
8. Fan exhaust openings
(not shown)
NOTE: Terminals 1 to 4: Quick Connect - Male,
6.3 mm / 1/4" at blade
Fig. 2 Layout (Front View)
WIRE SIZE (3 ft from Battery)
fUSE SpECS
(SEE notE 1 BEloW)
32V, 40A
32V, 30A
80V, 20A
125V, 10A
WIRE SIZE (3 ft from Battery)
fUSE SpECS
(SEE notE 1 BEloW)
32V, 30A
32V, 30A
32V, 30A
32V, 30A
32V, 15A
32V, 15A
32V, 15A
32V, 15A
58V, 7.5A
58V, 7.5A
DC-DC Converter Manual
83
mm
AWG#10
AWG#14
AWG#16
AWG#22
AWG#10
AWG#10
AWG#10
AWG#10
AWG#16
AWG#16
AWG#16
AWG#16
AWG#22
AWG#22
| 3