Installing the Sensor

!WARNING!
Before performing service or maintenance operations on
the systems, turn OFF main power switches to the unit.
Electric shock can cause personal injury. Please read and
follow the wiring instructions precisely; miswiring may
cause permanent damage to the product.
Basic Installation
1. Separate the case into its front and rear sections.
2. Secure the rear section of the case to the wall or junction box using
the supplied screws, and make necessary wire connections.
3. Mount the Controller on the base by aligning the top clips and then
securing to the bottom clips. Secure the Ventostat with the supplied
set screw. A one-minute stabilization warmup will take place.
J2
J3
8
7
Internal Label for Voltage Version
J2
7
6
Internal Label for 4-20 mA Version
STRIP GAUGE
6mm / ¼"
2
1
STRIP GAUGE
6mm / ¼"
2
1
Visit us at www.TestEquipmentDepot.com
Telaire T5100 Series
User Instructions
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
CO 2 Sensor
T63359-002
March 2014
Page 1 of 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T5100 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Telaire T5100 Series

  • Page 1 Amphenol Telaire T5100 Series CO 2 Sensor Advanced Sensors User Instructions Installing the Sensor !WARNING! Before performing service or maintenance operations on the systems, turn OFF main power switches to the unit. Electric shock can cause personal injury. Please read and follow the wiring instructions precisely;...
  • Page 2 As an alternative, please consider the T8031 unit. When mounting these products inside the ductwork, seal the hole around the wires and leave the duct insulation in place to prevent condensation which may damage the sensor. Page 2 Telaire T5100 Series...
  • Page 3 0 to 5 V, or 0 to 10 V jumper selectable (100  output impedance) Typical 0.7 W at nominal voltage of 24V AC RMS maximum 500 ) Or 4 to 20 mA (R Voltage and current outputs are not available simultaneously Digital to analog error ±1% Telaire T5100 Series Page 3...
  • Page 4 5,691,704 / 5,767,776 / 5,966,077 / 6,107,925 / 5,798,700 / 5,945,924 / 5,592,147 / 6,255,653 / 6,250,133 / 6,285,290 Warranty Repairs Amphenol Advaced Sensors will repair Telaire product that fails to meet the terms provided for in the Return and Warranty Policy Statement (See, http://www.telaire.com).Warranty period shall start from date of manufacture and be based on product category and type of equipment as specified in Table 1: Product Warranty Periods.

Table of Contents