Midea MEHSU-09CHD2 Service Manual page 60

Indoor/outdoor units
Table of Contents

Advertisement

Size of outline dimension mounted
Capacity(KBtu)
plug
mm
9
in
mm
12
in
mm
18
in
mm
24
in
mm
36
in
mm
48
in
12.2.1.3 Install the pendant bolt
Select the position of installation hooks
according to the hook holes positions showed
in upper picture.
Drill
four
holes
45~50mm(1.57~1.97in) deep at the selected
positions on the ceiling. Then embed the
expansible hooks (fittings).
12.2.1.4 Install the main body
Make the 4 suspender through the 4 hanger of
the main body to suspend it. Adjust the
hexangular nuts on the four installation hooks
evenly, to ensure the balance of the body. Use
a leveling instrument to make sure the
levelness of the main body is within ±1°.
12.2.1.5 Install the air filter
L
M
740
350
29.13
13.78
740
350
29.13
13.78
960
350
37.80
13.78
960
350
37.80
13.78
1180
490
46.46
19.29
1240
500
48.82
19.69
of
Ø12mm(0.47in),
Insert the air filter through the filter slot and fix it
with 2 screws.
12.2.1.6 Install the air duct
Please
design
recommended picture
12.2.1.7 Change the air inlet direction
① Take off ventilation panel and flange, cut off
the staples at side rail.
② Stick the attached seal sponge as per the
indicating place in the following fig, and then
change the mounting positions of air return
panel and air return flange .
58
the
air
duct
as
below

Hide quick links: