Required tools
Adjustable wrench
/
1
Small flat-bladed
Nut drivers:
precision screwdriver
To convert your for use with LP gas, perform the following steps and procedures:
1. Disconnect electrical power to the cooktop. Unplug the cooktop power cord, trip
the circuit breaker, or remove the fuse from the fuse box.
2. Shut off the gas supply to the cooktop. Close the manual shut-off valve to the
cooktop.
24 English
Install_NA9300K_DG68-00841A-01_EN+MES+CFR.indb 24
" open-end wrench
Screwdrivers: Phillips
2
/
" or 7
9
32
mm

Converting the pressure regulator

NOTE
If you are using LP gas to fuel the cooktop, the following steps and conversions
must be made before the flames can be adjusted.
1. Using your fingers, turn the cap. And carefully look at the spring retainer to
locate the NAT or LP position.
LP
Cap
NAT
LP
NAT
NAT. Position
Pressure Regulator
2. Turn the spring retainer over by rotating it 90 deg., pull it from the cap, turn the
spring retainer over so that LP is showing, insert it back into the cap, and then
rotate it 90 deg. Into position.
3. Screw the cap back onto the regulator and tighten.
NAT
Gasket
LP
Spring
NAT
Retainer
L.P./Propane
Position
LP