Sinclair SCMI-01 User Manual page 6

Usbcommunicator

Advertisement

Main menu
Submenu/Option
Target value
Setting of desired temperature; this menu is not accessible in the slave
mode.
Function
Operated
Reg. P
Reg. T*
Reg. T+
Defrost
Mode
Period
Length
Start
Stop
Outputs
Relay 1
Relay 2
Relay 3
DC Vent
Reg.cons
Time con
Prop.con
Int.cons
Der.cons
Display
Backlight
Contrast
Time gap
Language
Password
Enter the password before setting the module. After logging in, you can perform
setting for about 30 minutes. Without knowing the password, you can only adjust the
contrast and backlight brightness of the display.
After setting is done, click on "Write"
All saved parameters can be displayed by clicking "Read"
Slave unit mode. The module is controlled by an external voltage 0-
10V.
Autonomous pressure (evaporation temperature) control mode
Autonomous temperature control mode for cooling
Autonomous temperature control mode for heating
Off
Defrosting of indoor unit evaporator is not in use
External
Defrosting with external support (heating cable etc.)
Reverse
Defrosting by switching from cooling to heating
mode.
Setting the minimum time period between defrosting
cycles
Setting the maximum duration of defrosting
Setting the temperature to start defrosting
Setting the temperature to stop defrosting
Function
ON/OFF
Compres.
Defrost
Error
Heat/Cool
Limiting
Logic
Direct
Inverse
Function
This setting is the same as setting the Relay 1
Logic
This setting is the same as setting the Relay 1
Function
This setting is the same as setting the Relay 1
Logic
This setting is the same as setting the Relay 1
Fixed
Setting the speed and mode (Co, Fa, On) of the
indoor fan
Auto 1
Fan speed according to compressor speed 1:1
Auto 2
Fan speed of 60-200% of compressor speed
Off
Output not used
Setting the time constant of the module.
Setting the proportional constant of the module.
Setting the integral constant of the module.
Setting the derivative constant of the module.
Setting the LCD backlight.
Setting the LCD contrast.
Setting the time period of the operator inactivity
Setting the language version
Tab 1: Summary of the module settings
Relay is controlled by On/Off input.
Relay is controlled according to the
compressor
Relay is controlled according to the
operation (Heat/Cool)
Relay is controlled according to the
error state
Relay is controlled according to the
operation (Heat/Cool)
Relay
to
limit
the
compressor load.
Relay switches with direct logic
Relay switches with inverse logic
button to save all parameters in module memory.
button.
Range
Default
-10 to +60
+10,0°C
Operated
Off
0.1 to 99.9
1 hour
1.0 to 60.0
10 min
-20 to +5,0
-5,0°C
+3 to +25.0 +7,0°C
On/Off
long
lasting
Direct
Compres.
Direct
Error
Direct
Off
10 to 999
30 sec.
0 to 999
35
0 to 999
0
0 to 999
60
1 to 16
8
1 to 16
8
10 to 999
60
CZ / EN
EN
201201
Note:
p. 7
p. 8
p. 9
p. 10
p. 11
p. 12
p. 13
p. 14
p. 15
p. 16
p. 17
p. 18
p. 6