Page 1
SLT 100 10.04 - Operating instructions 50451882 11.15 1 0 0 S L T 1 0 0 S L T...
Page 2
Used before notices and explanations. Used to indicate standard equipment. Used to indicate optional equipment. Copyright Copyright of these operating instructions remains with JUNGHEINRICH AG. Jungheinrich Aktiengesellschaft Friedrich-Ebert-Damm 129 D-22047 Hamburg - Germany Tel: +49 (0) 40/6948-0 www.jungheinrich.com...
Operational safety and environmental protection Description of battery Safety instructions to charger be observed during servicing Cleaning operations Technical description Working on the SLT 100 Charging electronics charger Protection / Ambient conditions Fuses Identification label, Small battery charger Transportation and...
“Charger Assembly” on page 5. The technical data and specifications The user must ensure that the SLT 100 regarding the connection requirements can battery charger is used only within its be found on the identification plate and in...
Description of battery charger Technical description The SLT 100 battery charger is designed for the fully automatic charging and recharging lead batteries equipped with a special electronic charging system (1, 2). The rated charging current specified flows at a charging voltage of 2.0 volts per cell.
Page 7
Charging electronics extra option If the battery remains attached to the (Aquamatic) charger at the end of the charging time (T3), there will follow an 8 minute trickle The Aquamatic serves to control an charge every 8 hours and after 24 hours a external solenoid valve of an automatic one-off compensation...
- for operation 0 °C 12 11 If the charger thaws due to sudden temperature changes, leave the charger for The SLT 100 charging electronics monitor a least 3 hours before switching it on again. control charging operation. Progress of the charging operation is The charger must only be stored in shown by the light-emitting diodes (7).
Starting up the charger Charging cable connection: Always wear solid leather safety boots and gloves when transporting and assembling The SLT 100 charger is supplied with the charger. a charging cable. The charging cable connections with strain Before starting the charger make sure it is relief can be accessed when the yellow complete and in satisfactory working order.
Battery - Servicing, recharging, replacement Safety regulations governing Batteries contain dissolved acid, which is handling of lead-acid batteries toxic and caustic. For this reason protective clothing and goggles must be worn Maintenance personnel: whenever work is undertaken on batteries. Recharging, servicing and replacing of Avoid physical contact with battery acid.
Operation Safety regulations relating Charger assignment: operation of battery chargers The charging procedures, or charging characteristics, as well as the charging To ensure the safety of a battery charger, equipment must be adapted to the the equipment (charger, cables, battery) operating conditions and technical data of must be in good working order.
Description of the operating controls and indicating elements Item Operating control / Function indicating element “Standby” LED (green) lights up when the battery charger is ready for operation “Charging” LED indicates the charging process (yellow) Control key The control key has the following functions: - Stop / Continue charging (break function) - Manual equilising charge - Charging state indicator...
Commissioning the battery charger All LED displays go out. When the mains supply is restored the LEDs display the Connecting the charger previous condition. The battery charge continues. The stored charging indication, When connecting the charger, make sure however, will be lost, when a mains failure the contact of the charging cable is secure.
Manual charging interruption Manual Compensation Charge The battery charger must only be switched The battery charger has a “manual off using the control key (3) if charging is to compensation charge” function. be interrupted manually. Compensation charging should be carried This procedure will avoid malfunctions and out regularly (1x a week) in order to the charging connector cannot be damaged...
The fuses used depend on the model. The SLT 100 charger is maintenance-free. Small battery charger It does not need to be cleaned regularly. Any modification to the SLT 100 charger, in particular its safety mechanisms, is strictly prohibited. Only original spare parts have been passed by our quality assurance service.
Large battery charger - Primary: F2 control fuse contactors (18) Secondary: F1 fuse (3) electrolyte circulation pump/ Aquamatik (o): F3 fuse (17) - D400V devices without neutral conductor: F12 fuse (19) Version and rated value of the fuses must not be changed. Refer to label showing the rated values.
Internal electrolyte stirrer (EUW) Correct use and application Electrolyte circulation (EUW) During charging the electrolyte circulation See also Chapter A ,“Correct use and pump is switched on for approx. 2.5 min. application”. and off for approx. 7 min. The battery charging device with a built-in Charging is recognised by the charge pump and hose system is suitable only for switch insofar as it:...
Page 18
The internal electrolye stirrer consists of the If the system is working correctly and the following parts: recharging time is reduced, the green LED (1) is lit on the control board. - An additional switch contact to switch on the pump; A defective hose system can be identified via the air pressure monitor.
"Air volume flow presetting” on page 15. Air volume flow presetting Switch (3) has the following factory settings for all SLT 100 large battery chargers: Voltage class Volume in l/min in V Figure: Small battery charger...
Aid for malfunctions Malfunction: Charging time reduced Faults may only be rectified by skilled electricians in compliance with safety Possible causes: regulations. Remove the battery and mains - The hose system defective plugs before opening the charger. (see “Air pressure monitor” on page 14). - Filter (5) is clogged.
“LIS” charge information system (o) Chargers with the charge information system (LIS) store the data from the last 200 charges. The curves for the individual charges can be viewed on a PC. The necessary software is supplied on a CD with the charge information system.
Sample data plate Item Designation Item Designation Series No. of cells/type Type Protection class Serial No. Output Year of manufacture Battery capacity Fuse Manufacturer Input...
Need help?
Do you have a question about the SLT 100 and is the answer not in the manual?
Questions and answers