AEMC PEL 105 User Manual

Power & energy logger
Hide thumbs Also See for PEL 105:
Table of Contents

Advertisement

Quick Links

Power & Energy Logger
Model PEL 105
User Manual
ENGLISH
PowerMeterStore
1.877.766.5412
www.
.com
Shop for Power Metering products online at:

Advertisement

Table of Contents
loading

Summary of Contents for AEMC PEL 105

  • Page 1 Power & Energy Logger Model PEL 105 User Manual ENGLISH PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 2 Chauvin Arnoux , Inc, AEMC , DataView , AmpFlex , and MiniFlex are registered trademarks of AEMC Instruments. ® ® ® ® ®...
  • Page 3: Precautions For Use

    Thank you for purchasing a Power Energy Logger Model PEL 105. For best results from your instrument and for your safety, read the enclosed operating instructions carefully and comply with the precautions for use. These products must be only used by qualified and trained users.
  • Page 4: Table Of Contents

    4.1.4 3-Phase 3-Wire ∆ (3 current probes) (3P-3W∆3) ..................25 4.1.5 3-Phase 3-Wire Open ∆ (2 current probes) (3P-3WO2) ................26 4.1.6 3-Phase 3-Wire Open ∆ (3 current probes) (3P-3WO3) ................26 4.1.7 3-Phase 3-Wire Y (2 current probes) (3P-3WY2) ..................26 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 5 6.1 Installing DataView ..............................58 6.2 The PEL Control Panel ............................61 6.3 Connecting to the Computer ..........................61 6.3.1 USB ................................62 6.3.2 Bluetooth ..............................62 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 6 8.1.2 Upgrading Firmware ..........................78 8.1.3 Battery Maintenance ..........................80 8.1.4 Cleaning the Instrument ..........................80 8.2 Troubleshooting ..............................80 8.2.1 Instrument Does Not Turn ON........................80 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 7 APPENDIX B: MEASUREMENT QUANTITIES ..............88 APPENDIX C: POLE MOUNTING ..................96 GLOSSARY ........................98 Limited Warranty ......................101 Warranty Repairs ......................101 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 8: Introduction

    1.1 Receiving Your Shipment Upon receiving your PEL 105 product package, ensure the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, providing a detailed description.
  • Page 9: Accessories

    USB SD-card Adapter ............................Cat. #5000.45 DataView Software and Instrument Firmware Updates ® Available at www.aemc.com PEL Android App Available on the Google Play Store at https://play.google.com/store/apps/details?id=com.aemc.pel&hl=en Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 10: Features

    2. FEATURES 2.1 Description The Power & Energy Logger Model PEL 105 provides all the necessary functions and features for recording power/energy data for most 50Hz, 60Hz, 400Hz, and DC distribution systems worldwide. The instrument is designed for full outdoor or indoor use, resistant to both water (IP67) and sunlight (UL746C f1).
  • Page 11: Front Panel

    7. Overload LED 16. LCD Screen 8. SD Card LED 17. Directional Buttons (Up, Down, Left, Right) 9. Wi-Fi LED 18. Enter button Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 12: Input Terminals

    Detach the appropriate inserts and place them in the holes provided over the terminals (larger inserts for current terminals, smaller inserts for voltage terminals). ■ Clip the rings of the same color to the ends of the lead you will connect to the terminal. Figure 3 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com...
  • Page 13: Button Functions

    NOTE: In this manual, the symbol indicates when you need to press a button to perform a task. For example, represents “press the Control button. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 14: Lcd Screens

    LCD automatically enters Backlight Standby mode. In this mode, measurements and recordings stay active but the LCD backlight turns OFF. To restore the backlight, press any navigation button. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412...
  • Page 15: Led Status Indicators

    (described in § 2.4) glows green when the instrument is running on phase voltage power, In addition, the Power and blinks red once per second when phase voltage power is disabled. (See also § 3.1.1.) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 16: Installing The Sd Card

    When the card is installed and ready for use, the LED glows steady green. To remove a card, press down on it until the card unclicks. It will pop up, allowing you to pull it from the slot. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 17: Set Up & Configuration

    Pressing simulta- neously for two seconds re-enables this feature. You can also disable and enable this feature through the DataView PEL Control Panel (see § 6). Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 18: Charging The Battery

    3.2 Charging the Battery The PEL 105 is equipped with a NiMH battery, which provides power in the event of a disruption in the phase power or external AC power. Before the first use, start by fully charging the battery.
  • Page 19: Bluetooth Enabling And Disabling

    5. De-select the checkbox “Lock out the Control button on the instrument front panel.” 6. Click OK to save the change. Consult the PEL Control Panel Help system for assistance in completing the preceding steps. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 20: Configuration Mode

    If any of these situations is in effect, the word LOCK appears on the screen: Figure 6 Otherwise, the Hookup configuration screen appears: Figure 7 This is the top-level screen in Configuration mode, and serves as the starting point for all configuration tasks. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com...
  • Page 21: Selecting The Hookup

    3P-4WY2 3-phase 4-wire Y 2½ 3P-4WYb 3-phase 4-wire Y balanced (fixed, voltage measurement) 3P-4WY 3-phase 4-wire Y 3-phase 3-wire ∆ balanced 3P-3W∆b Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 22: Selecting Nominal Current And Voltage

    6. Press ▼ to display the Secondary Nominal Voltage (PT SEC) configuration screen. This functions similarly to the Primary Nominal Voltage screen. Allowable secondary nominal voltage values range from 50 to 1000V. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412...
  • Page 23 Current configuration screen displays the Primary Neutral Current screen. This screen functions similarly to the Primary Nominal Current screen. Allowable values are: AmpFlex/MiniFlex: 100, 400, 2000, or 10000A BNC Adapter: 1 to 25000A Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 24: Setting The Aggregation Period For A Recording

    Primary nominal neutral current (when available) ■ Aggregation period ■ Date and time ■ LAN IP address ■ WiFi IP address ■ Firmware revision number Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 25: Operation

    4.1 Hooking Up to the Distribution System The Model PEL 105 works with a variety of current probes and sensors. Choosing which type to use depends on the cur- rent to be measured and the diameter of the electrical cables. Each probe and sensor comes with its own documentation, which you should consult before connecting to the instrument.
  • Page 26: Single-Phase 2-Wire (1P-2W)

    V1 test lead to L1. ■ IN probe to neutral (optional, normally not used in this hookup). ■ I1 probe to L1. VE/GND Figure 13 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 27: Single-Phase 3-Wire (1P-3W)

    V3 test lead to L3. ■ I1 probe to L1. ■ I2 probe to L2. ■ I3 probe to L3. VE/GND Figure 16 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 28: 3-Phase 3-Wire Open ∆ (2 Current Probes) (3P-3Wo2)

    V2 test lead to L2. ■ V3 test lead to L3. ■ I1 probe to L1. ■ I3 probe to L3. VE/GND Figure 19 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 29: 3-Phase 3-Wire Y (3 Current Probes) (3P-3Wy3)

    IN probe to neutral. ■ I1 probe to L1. VE/GND ■ I2 probe to L2. Figure 22 ■ I3 probe to L3. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 30: 3-Phase 4-Wire Y Balanced (3P-4Wyb)

    IN probe to neutral. ■ I1 probe to L1. VE/GND ■ I2 probe to L2. Figure 25 ■ I3 probe to L3. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 31: 3-Phase 4-Wire Open ∆ (3P-4Wo)

    ■ IN probe to the common conductor. ■ I1 probe to conductor +1. ■ I2 probe to conductor +2. VE/GND Figure 28 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 32: Dc 4-Wire (Dc-4W)

    ■ I3 probe to conductor +3. 4.2 Viewing Data The PEL 105 provides four data viewing modes: ■ Measurement mode displays real-time data currently being measured by the probes/sensors. This includes voltage, current, power, frequency, power factor, and tangent angle.
  • Page 33: Measurement Mode

    4.2.1.1 1-Phase 2-Wire (1P-2W) ϕ (I Active power/current/voltage Phase angle (1-phase 2-wire) (1-phase 2-wire) Frequency (1-phase 2-wire) Power (1-phase 2-wire) Tangent (1-phase 2-wire) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 34: 1-Phase 3-Wire (1P-3W)

    Voltage (1-phase 3-wire) Voltage phase angle (1-phase 3-wire) ϕ (I ϕ (I Power (1-phase 3-wire) Phase angles between line currents/voltages (1-phase 3-wire) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 35: 3-Phase 3-Wire Unbalanced

    (3-phase 3-wire unbalanced) (3-phase 3-wire unbalanced) ϕ (U ϕ (U ϕ (U Phase voltage/frequency Phase voltage phase angles (3-phase 3-wire unbalanced) (3-phase 3-wire unbalanced) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 36 4. Press ◄ or ► until the icon is selected. This displays the first measurement screen for a 3-phase 3-wire unbalanced hookup (Line current). 5. Navigate through the measurement screens as instructed in the table above. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 37: 3-Phase 3-Wire ∆ Balanced (3P-3W∆B)

    Power Phase angle between (3-phase 3-wire ∆ balanced) line current and phase voltage (3-phase 3-wire ∆ balanced) Tangent (3-phase 3-wire ∆ balanced) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 38: 3-Phase 4-Wire Unbalanced

    ϕ (U ϕ (U ϕ (U Phase voltage/frequency Phase angles between (3-phase 4-wire unbalanced) line currents and phase voltage (3-phase 4-wire unbalanced) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 39 4. Press ◄ or ► until the icon is selected. This displays the first measurement screen for a 3-phase 4-wire unbalanced hookup (Line current). 5. Navigate through the measurement screens as instructed in the table above. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 40: 3-Phase 4-Wire Y Balanced (3P-4Wyb)

    Phase voltage/frequency (3-phase 4-wire Y balanced) ϕ (I Power Phase angles between (3-phase 4-wire Y balanced) line current/voltage (3-phase 4-wire Y balanced) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 41: Dc 2-Wire (Dc-2W)

    3. Hook up the probes and sensors to the DC 2-wire distribution system, as instructed by § 4.1.15. 4. Press ◄ or ► until the icon is selected. This displays the measurement screen for a DC 2-wire hookup (Active power/current/voltage). Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 42: Dc 3-Wire (Dc-3W)

    4. Press ◄ or ► until the icon is selected. This displays the first measurement screen for a DC 3-wire hookup (Line current). 5. Navigate through the measurement screens as instructed in the table above. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 43: Dc 4-Wire (Dc-4W)

    4. Press ◄ or ► until the icon is selected. This displays the first measurement screen for a DC 4-wire hookup (Line current). 5. Navigate through the measurement screens as instructed in the table above. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 44: Energy Mode

    Press ▼ to restore the display of full values. There are two sets of Energy mode screens, one for AC hookups and one for DC. 4.2.2.1 AC Energy Screens Consumed (Load) active energy (AC hookup) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com...
  • Page 45 Q. Reactive energy on Quadrant 1 (Inductive Import) Reactive energy on Quadrant 2 (Capacitive Export) Reactive energy on Quadrant 3 (Inductive Export) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 46 Reactive energy on Quadrant 4 (Capacitive Import) Consumed (Load) apparent energy Generated (Source) apparent energy Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 47: Dc Energy Screens

    4.2.2.2 DC Energy Screens Consumed (Load) active energy (DC hookup) Generated (Source) active energy (DC hookup) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 48: Harmonics Mode

    Total Harmonic Distortion (1-phase 2-wire) 4.2.3.2 1-Phase 3-Wire (1P-3W) THD_I THD_I Current THD (1-phase 3-wire) THD_V THD_V THD_U Voltage THD (1-phase 3-wire) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 49: 3-Phase 3-Wire Unbalanced

    3P-3WY3 (3-phase 3-wire Y, three probes) THD_I THD_I THD_I Current THD (3-phase 3-wire unbalanced) THD_U THD_U THD_U Voltage THD (3-phase 3-wire unbalanced) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 50: 3-Phase 3-Wire ∆ Balanced (3P-3W∆B)

    3P-4WY2 (3-phase 4-wire Y, two probes) ■ 3P-4W∆ (3-phase 4-wire ∆) ■ 3P-4WO (3-phase 4-wire open ∆) THD_I THD_I THD_I Current THD (3-phase 4-wire unbalanced) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 51: 3-Phase 4-Wire Balanced (3P-4Wyb)

    (3-phase 4-wire unbalanced) 4.2.3.6 3-Phase 4-Wire Balanced (3P-4WYb) THD_I THD_I THD_I Current THD (3-phase 4-wire balanced) THD_V THD_V THD_V Voltage THD (3-phase 4-wire balanced) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 52: Maximum Mode

    Note that Maximum mode is not available for DC power networks. 4.2.4.1 1-Phase 2-Wire (1P-2W) Maximum current/voltage (1-phase 2-wire) Maximum load power (1-phase 2-wire) Maximum source power (1-phase 2-wire) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 53: 1-Phase 3-Wire (1P-3W)

    4.2.4.2 1-Phase 3-Wire (1P-3W) Maximum current/voltage (1-phase 3-wire) Maximum current/voltage (1-phase 3-wire) Maximum load power (1-phase 3-wire) Maximum source power (1-phase 3-wire) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 54: 3-Phase 3-Wire

    3P-3WY3 (3-phase 3-wire Y, three probes) ■ 3P-3W∆b (3-phase 3-wire ∆ balanced) Maximum line current (3-phase 3-wire) Maximum line voltage (3-phase 3-wire) Maximum load power (3-phase 3-wire) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 55: 3-Phase 4-Wire

    Note that for 3-phase 4-wire Y balanced hookups, the maximum neutral current (I ) is not dis- played. Maximum line current (3-phase 4-wire) Maximum voltage (3-phase 4-wire) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 56 Max. phase-to-phase voltage (3-phase 4-wire) Maximum load power (3-phase 3-wire) Maximum source power (3-phase 3-wire) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 57: Recording Data

    200ms trends, 1 second trends, and harmonics from the download. Doing so reduces the data downloaded from a 30 day recording with 15-minute aggregation to 3.4MB. (You can choose which recorded data to include/exclude in the download via the PEL Control Panel.) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 58: Starting And Stopping A Recording

    3. To stop a recording, press and hold it down until the LED lights up, then release To view the recording session, connect the instrument to your computer running DataView (see § 6). Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 59: Dataview ® & Pel Control Panel

    ® DataView enables a computer to connect to and interact with a variety of AEMC instruments, including the Model PEL 105. As its name implies, the primary purpose of DataView is to view data that has been recorded by the instrument and display it as a report.
  • Page 60: Installing Dataview

    DataView software version releases. Similarly, Firmware Upgrades links to the website where you can check for new firmware updates for the PEL 105 (see § 8.1.2). Finally, User Manuals displays a printable .pdf file containing the documentation that accompanies DataView. (DataView also comes with a Help system that is installed with the program files.)
  • Page 61 7. The next screen lets you select the DataView setup. If you choose Custom, you are prompted to select individual DataView components to install. To install the full DataView product, select Complete and then click Next. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412...
  • Page 62 Control Panels are selected. Control Panels take up disk space on the computer; so unless you have other types of AEMC instruments, we recommend that you select PEL and deselect the rest. You should also check the option PDF-XChange, which is a requirement if you plan to create .pdf versions of DataView reports.
  • Page 63: The Pel Control Panel

    ■ Wi-Fi direct connection ■ Ethernet point-to-point cable connection ■ Network connection via LAN or Wi-Fi ■ Network connection via IRD server Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 64: Usb

    3. Find the instrument, which will appear listed by its Bluetooth name. This name consists of the prefix “PEL 105” plus any additional characters you add via the PEL Control Panel. Click the name. 4. You are prompted to enter a pairing code, which for PEL 105 instruments is always 0000. After you enter the code, click Next.
  • Page 65: Wi-Fi Direct Connection

    6.3.3 Wi-Fi Direct Connection The PEL 105 can also connect via Wi-Fi, either directly to the computer or via a router (see § 6.3.6). To directly connect, Wi-Fi must be enabled on the instrument. Check the Wi-Fi LED. If it is glowing steadily or blinking, Wi-Fi is enabled. If...
  • Page 66: Network Via Ird Server

    5. You can synchronize the instrument’s clock with the computer’s clock, or use the Date and Time fields to select another date and time. 6. Click OK to save the change. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 67: Specifications

    < 0.1% Voltage unbalance Internal temperature Warm up: 1 hour Neutral input and enclosure are held at ground (earth) potential Common mode PEL 105 powered on battery, USB disconnected Magnetic field 0 A/m AC Electric field 0 V/m AC Table 1 7.2 Electrical Specifications...
  • Page 68: Measurement Ranges

    Tan ϕ Tan ϕ = 3.2 inductive; 3.2 capacitive V = 100 to 1000V ± 0.05 I = 5 to 120% I Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 69: Measurement Specifications At 400Hz

    PF = 0.5 inductive 0.8 capacitive V = 100 to 600V ± (3% Rdg + 0.3% P  I = 5 to 120% I Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 70: Measurement Specifications For Dc

    When there is no current probe, the uncertainty for neutral current I is the sum of the uncertainties on I , and I Table 4 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 71: Temperature

    -0.5° @ 5A 5 to 250mA ± (0.5% Rdg +2mA) ± 0.5° Adapter 250mA to 6A ± (0.5% Rdg +1mA) ± 0.5° Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 72: Ampflex ® /Miniflex

    Rx sensitivity: -97dBm ■ Security: WPA/WPA2 ■ Client (STA) mode support ■ Access Point (AP) mode support for up to five clients Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 73: Power Consumption

    IP54 with caps when the cover is open in the horizontal position and under operating conditions. IP40 without caps when the cover is open in the horizontal position and under operating conditions. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412...
  • Page 74: Environmental

    The instrument is protected internally by 1000V fuses against excessive current being drawn from the phase power supply due to faulty equipment or transient overvoltages. These fuses can only be replaced by authorized AEMC service personnel. 7.8 Electromagnetic Compatibility ■...
  • Page 75: Ampflex Model A196-24-Bk

    ≤ 2% near the snap device current 600V CAT IV, 1000V CAT III, EN 61010-2-032, Rating and Safety Pollution Degree 2 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 76: Model J93

    300V CAT IV, 600V CAT III, EN 61010-2-032, Rating and Safety Pollution Degree 2 9V alkaline (battery life 70 hours; typical Battery consumption 11mA) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 77: Model Mn93-Bk

    Adjacent conductor carrying alternating < 10mA/A at 50/60Hz current 600V CAT IV, 1000V CAT III, EN 61010-2-032, Rating and Safety Pollution Degree 2 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 78: Model Mn193-Bk

    300V CAT IV, 600V CAT III, EN 61010-2-032, Rating and Safety Pollution Degree 2 7.10.8 Model SL261 This probe requires a BNC Adapter (catalog #2140.40) for use with the PEL 105. AC/DC Current Probe Model SL261 Nominal range 10A and 100A...
  • Page 79: Voltage Test Leads

    7.11 Voltage Test Leads The PEL 105 ships with five black test leads and alligator clips. Voltage Test Leads and Alligator Clip Length 3m (approximately 10’) Rating 1000V CAT IV, 15A Each lead includes a waterproof cap that screws into the instrument’s threaded voltage terminals to ensure a water-tight (IP67) connection.
  • Page 80: Maintenance & Troubleshooting

    LED glows steady green. 8.1.2 Upgrading Firmware Periodically AEMC may release new firmware for the PEL 105. This firmware controls the features and functionality of the instrument. We recommend checking for firmware upgrades on a regular basis, to ensure your instrument has the most current version.
  • Page 81 Software and Firmware Updates. 2. In the Firmware Downloads section of the Downloads page, find the entry for PEL 105 firmware. This entry includes a link to the firmware, along with the firmware revision number and its release date. Compare this revision number to the one listed in the Firmware screen.
  • Page 82: Battery Maintenance

    ■ Comply with the instrument usage and storage conditions defined in § 1. Note that you cannot change the battery. This must be done at an authorized AEMC Service Center as part of the instru- ment’s regular maintenance. 8.1.4 Cleaning the Instrument The instrument should be cleaned periodically.
  • Page 83: Instrument Turns On But Does Not Function

    Check the appropriate LED: for Wi-Fi, for Bluetooth. If it is OFF (indicating the protocol is disabled) enable it as instructed in § 3. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 84: Cannot Turn Off The Instrument

    If you are attempting to connect via Bluetooth but you cannot connect the instrument via the PEL Control Panel – for exam- ple, the PEL 105 does not appear as available when you attempt to connect with it – the instrument may not be paired with the computer.
  • Page 85: Appendix A: Theory Of Operation

    V . If V is missing, the instrument attempts to lock sampling frequency V , then V , and I Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 86: Locking The Sampling Frequency

    I A.1.2 AC/DC The PEL 105 makes AC and DC measurements for AC and DC distribution networks. AC or DC is selected by the user. The AC + DC values are available via the DataView PEL Control Panel. A.1.3 Neutral Current Measurement Depending on the distribution network, if there is no current sensor on the I terminal, the neutral current is calculated.
  • Page 87: Energy Calculations

    3P-3W∆b (3-Phase 3-Wire ∆ balanced) 3P-4WY ), ϕ (I ), ϕ (I [ϕ (I )] = 120° ± 30° (3-Phase 4-Wire Y) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 88: Voltage Phase Sequence

    ) = 180° ± 10° Yes (on U) [ϕ (U ), ϕ (U ), ϕ (U )] = 120° ± 10° 3P-4WO∆ (3-Phase 4-Wire Open ∆) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 89: Current Vs Voltage Phase Sequence

    [ϕ (I )] = 210° ± 60° for source 3P-4WO∆ (3-Phase 4-Wire Open ∆) DC-2W (DC 2-Wire) DC-3W (DC 3-Wire) DC-4W (DC 4-Wire) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 90: Appendix B: Measurement Quantities

     AC RMS          AC RMS         Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 91    (10)                   Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 92   (10)                    Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 93         (10)              Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 94  ϕ          ϕ          (10) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 95 50             (11) -THD       Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 96        ϕ(I       ϕ(I        Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 97 (4) Always = 0 (11) Calculated or measured if a current sensor is con- (5) AC+DC when selected nected (6) Rank 7 for 400Hz Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 98: Appendix C: Pole Mounting

    APPENDIX C: POLE MOUNTING Accessory brackets (Cat. #2137.81) enable you to mount the Model PEL 105 on a utility pole or similar structure. Figure 37 To mount the instrument on a pole, turn it OFF and detach all leads and other connections. Then do the following: 1.
  • Page 99 4. Run two straps (not included) through the slots in the brackets. These slots are 25.4 x 4mm (1 x 0.157”). 5. Position the instrument on the pole, and attach it by fastening the straps. Figure 40 Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www.
  • Page 100: Glossary

    Line (phase). For example, L is line 1 or phase 1. Maximum value. Typically, this represents the maximum measurement during a specified time interval. Minimum value. Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 101 Reactive power, expressed in volt-amperes. VArh Reactive energy, expressed in volt-amperes. Phase-to-neutral voltage harmonic. Voltage at neutral (V Unit of measure for power. (Watt) Power & Energy Logger Model PEL 105 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 102 PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...
  • Page 103: Limited Warranty

    LIMITED WARRANTY The Model PEL 105 is warranted to the owner for a period of one year from the date of original purchase against defects in manufacture. This limited warranty is given by AEMC Instruments, not by the distributor from whom it was purchased.
  • Page 104 99-MAN 100427 v1 - 02/16 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® PowerMeterStore 1.877.766.5412 www. .com Shop for Power Metering products online at:...

Table of Contents