5.

Maintenance

5.1.

Cleaning

CV3516 operates relatively maintenance free. However, it should be
cleaned at regular intervals especially if it is operating in an environment
with high levels of dust, smoke or nicotine. The cleaning intervals are of
course dependent on the level of air borne contaminants.
Modest use with minimum contaminant levels indicate the need to clean
the top of the coin path once a year. Open the coin path door and wipe
the exposed surfaces with a cloth moistened with lukewarm water and a
little washing-up liquid. The light sensors may be cleaned with a soft brush
or air duster spray.
The consumption of current is raised for short period of time (40 ms)
when the solenoid is activated. Make sure that the voltage does not drop
below 8 volts when a load of 400 mA is applied.
Make sure that the coin validator is without power during the
cleaning
Use a damp - not wet - cloth. Under no circumstances liquid
should run into the coin validator
Avoid solvent or abrasives which may ruin the plastic material
Never use an oily rag! Never lubricate the solenoid, hinge
joints, etc.
user guide CV3516
page 10/14