WIRELESS REFRIGERANT CHARGING SCALE
WIRELESS REFRIGERANT CHARGING SCALE WITH SOLENOID
A. Notice: The changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
B. IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the
device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure
requirements and void user's authority to operate the device.
C. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
KEY FUNCTIONS:
SYNC:
UNITS/SHIFT:
CHARGE/PAUSE:
TARE/ENTER:
REPEAT:
CLEAR:
CHECKLIST (Prior to 1st use)
Install battery in both platform and monitor. Place the platform on a flat surface and press the ON/OFF button on the
platform and monitor to turn unit on. Proceed to BASIC or PROGRAM CHARGING.
PLEASE NOTE: After turning ON the scale or replacing batteries, there will be a 3 second delay in displaying the scale's
battery level, if the power LED in the scale remains on (without blinking), the scale has normal working status.
* If the digital readout displays a small weight (±.5 ounce or ±20 grams) press and hold the TARE/ENTER button for
approximately 3 seconds until you hear a DOUBLE BEEP. The scale will automatically zero out. Proceed to BASIC or
PROGRAM CHARGING.
SYNCHRONIZATION
When "No Signal" is displayed, it indicates synchronization is disabled or channel is wrong. Synchronize monitor with
platform by following the procedure below:
1. Press SYNC button on platform, power LED and SYNC LED will blink.
2. Press SYNC button on monitor, display will show "SYNC."
3. If synchronization is successful, display will show "good" and the power LED and SYNC LED on the platform will stop
blinking.
4. Resume BASIC CHARGING.
BASIC CHARGING
1. Place platform on level surface.
2
OPERATING INSTRUCTIONS
Turns unit ON or OFF
To synchronize platform with monitor
UNITS - Select readout in lb, oz or kg
SHIFT - Move from one digit to the next, to edit display, to set up tank
capacity
To increase value
To decrease value
CHARGE - To start CHARGE/RECOVERY mode
PAUSE - To pause and resume in CHARGE/RECOVERY mode
TARE - Zeros out display in BASIC CHARGING
ENTER - To start operation or input data
To repeat the last action
Use to clear the display during PROGRAM CHARGE ONLY. (Do not use clear for any other
function!)