ADDENDUM: USEFUL EQUATIONS AND CONVERSIONS
Area equation for rectangular or square ducts
Width (W)
Area equation for circular ducts
Radius
Cubic equations
must be converted to feet or meters before using the above formulae.
Unit of Measure Conversion Table
1 m/s
1 ft/min
0.00508
1 knot
1 km/h
1 MPH
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
FAX 781.665.0780 - TestEquipmentDepot.com
Height (H)
Area (A) = Width (W) x Height (H)
3
CFM (ft
/min) = Air Velocity (ft/min) x Area (ft
CMM (m
3
/min) = Air Velocity (m/sec) x Area (m
NOTE: Measurements made in inches
m/s
ft/min
1
196.87
1
0.5144
101.27
0.2778
54.69
0.4464
87.89
Back to the 451112 Product Info Page
Visit us at www.TestEquipmentDepot.com
6
2
Area (A) =
x r
6
Where
= 3.14 and r
radius
knots
1.944
0.00987
1
0.54
0.8679
4
2
= radius x
2
)
2
) x 60
km/h
MPH
3.6
2.24
0.01829
0.01138
1.8519
1.1523
1
0.6222
1.6071
Model 451112 Version 2.4 2/04