  • Page 1 I n s t a l l a t i o n a n d o p e r a t i o n i n s t r u c t i o n s . R O T E X S a n i c u b e : Hot water indirect cylinder.
  • Page 2 12 Polypropylene outer container 13 Unpressurized storage water The ROTEX SANICUBE hot water indirect The stored water can be heated in a cylinder is an entirely new product of its kind, variety of ways, i.e.: developed on the basis of the latest priciples of water hygiene and heating technology.
  • Page 3: Economical Operation

    A d v a n t a g e s The SANICUBE tank is a combination of a hot Hygienically optimised water Minimal limescale water indirect cylinder and instantaneous water heater. In this entirely new design With the SANICUBE hot water indirect In the stored water compartment, it is only concept lie the special advatages of the cylinder, slow-flowing or inadequately heated...
  • Page 4 I n s t a l l a t i o n a n d c o n n e c t i o n Place the tank on an even and smooth floor. Illustration 1 Cold water Connection scheme: The cold water connection has to be installed 1 Storage tank according to DIN 1988 (see illustration).
  • Page 5: Heat Exchanger

    H o t w a t e r i n s t a l l a t i o n Basically, generators of sanitary water should To avoid a possible discharge by gravity circu- Heat exchanger be placed as near as possible to the bleeding lation, a nonreturn valve must be installed wit- points.
  • Page 6: Operation

    Heating up with an immersion heater 2 - 6 kW. Fig. 9: SC 580/0 Außerdem steht der Sanicube in modfizierter Ausführung als Solarspeicher Sanicube Solaris ebenfalls in drei Varianten zur Verfügung (siehe Technische Unterlagen ROTEX Solaris- System). [ 6 ]...
  • Page 7 Te c h n i c a l d a t a Sanicube Warmwasserspeicher Heat insulation of the cylinder tank Type SC 580/0 SC 580/1 SC 580/2 Middle specific drop effciency 1,4 W/K Ref.-no. 16 50 00 16 5014 16 45 09 Standstill temperature decrease 0,1 K/h Empty weight...
  • Page 8 Pressure loss in the sanitary heat exchanger depending on the withdrawal quality. ROTEX Environmental Management R O T E X H e a t i n g S y s t e m s G m b H Langwiesenstraße 10 · D-74363 Güglingen Whiteshill House ·...

This manual is also suitable for:

Sanicube sc 500Sanicube sc514