Display Of Malfunction Analysis-4 [C8] - Panasonic EP-MA73 Service Manual

Massage lounger
Hide thumbs Also See for EP-MA73:
Table of Contents

Advertisement

5.7.

Display of malfunction analysis-4 [C8]

It is shown in which sensing is when the abnormal stop occurred.
1. Proceed the procedures of 5.1. Preparation of Secret Mode.
2. Push the button of BACK INTENSITY till C7appears, and push the OK button. Any of the following is shown.
Entry
Type
No.
C8
Display of the kinds of sensor
abnormal
*U10 display does not mean abnormal stops. Therefore, it is not memorized in the Microcomputer.
Operation mode
It is shown at which sensor opera-
tions the Massage block stopped.
Explanation of the summary
13
Condition
Display
Contents
00
Normal
01
Up/down sensor detects no
change.
02
Up/down sensor detects abnor-
mal change.
03
Abnormal sensing in the begin-
ning of the Up/down motor
04
Width
sensor
detects
change.
05
Width sensor detects abnormal
change.
06
Abnormal sensing in the begin-
ning of the Width motor
07
Intensity sensor detects no
change.
08
Intensity sensor detects abnor-
mal change.
09
Abnormal sensing in the begin-
ning of the Intensity motor
10
Abnormal rotation speed of the
Tapping motor
11
Normal Ottoman sensor
12
Ottoman sensor detects abnor-
mal change.
13
Reclining sensor detects no
change.
14
Reclining
sensor
abnormal change.
15
Massage block heater error
16
Foot heater error
no