Notice The information in this document is provided for reference only. ACCES does not assume any liability arising out of the application or use of the information or products described herein. This document may contain or reference information and products protected by copyrights or patents and does not convey any license under the patent rights of ACCES, nor the rights of others.
Page 3
Terms and Conditions If a unit is suspected of failure, contact ACCES' Customer Service department. Be prepared to give the unit model number, serial number, and a description of the failure symptom(s). We may suggest some simple tests to confirm the failure.
The card occupies 32 bytes of I/O address space. The base address is selectable via jumpers anywhere within the range of 100-3E0 hex. An illustrated setup program is provided with the card. Interactive displays show locations and proper settings of jumpers to set up board address and interrupt levels. Manual 104-QUAD-8...
Differential filter of 120Ω in series with 4700pF per channel. -RoHS This product is available in a RoHS compliant version. Please call for specific pricing then be sure to add this suffix to the model number on any hard-copy or verbal purchase orders. Manual 104-QUAD-8...
Screw terminal board, 34 pin male header DIN-SNAP6 DIN-rail mounting for one STB-34 104-HDW-KIT(x) PC/104 mounting hardware kit includes standard 4/40 (x=S for standard), (x=M for metric) standoffs and pan-head phillip screws for securing into PC/104 stack Manual 104-QUAD-8...
START | RUN and type , click OK or press . Follow the on-screen prompts to install the software for this board. LINUX Please refer to linux.htm on the CD-ROM for information on installing under linux. Manual 104-QUAD-8...
Check that all connections in your PC/104 stack are correct and secure then power up the system. Run one of the provided sample programs appropriate for your operating system that was installed from the CD to test and validate your installation. Figure 2-1: PC/104 Key Information Manual 104-QUAD-8...
Interrupts are directed to levels #2 through #7, #10 through #12, and #15 by a jumper at locations labeled IRQ2 through IRQ7, IRQ10 through IRQ12, and IRQ15. Figure 3-1: Setup Configuration Map Manual 104-QUAD-8...
Addr. Line Controlled Jumper Selection Table 4-2: Hex Conversion Table Carefully review the address selection reference table on the preceding page before selecting the board address. If the addresses of two installed functions overlap, you will experience unpredictable computer behavior. Manual 104-QUAD-8...
Reserved for Factory Use Base Address +16 Index Input Levels Read Only Base Address +17 Differential Encoder Cable Status Read/Write Base Address +18 CPLD Revision Read Only Base Address +19 through +1F Reserved for Factory Use Table 5-1: Base Address Map Manual 104-QUAD-8...
Bit 5 U/D: Up/Down flag. Set to 1 when counting up and reset to 0 when counting down. Bit 6 IDX: Index. Set to 1 when selected index input is at active level. Bit 7: Not used is always 0. Manual 104-QUAD-8...
Set both bits high to use FLG1 as Index (active high). Bits 5 & 6: Set bit 5 low and bit 6 high. Bit 7: Set high to program both counters simultaneously. Note that when Interrupts are enabled on the card they occur whenever FLG1 is active. Manual 104-QUAD-8...
A read from this address will return it’s contents. Bit 0: Set high to reset all Counters. Set low to enable all Counters. Bit 1: Reserved. Bit 2: Set low to disable the interrupt function. Set high to enable the interrupt function. Bits 3-7: Reserved. Manual 104-QUAD-8...
Bits 0 through 7 will always read a high when disabled. Reading the CPLD Revision Register (18h) To determine the CPLD Revision read from address 18h Old card revisions B10 and earlier will read FF Revision C1 cards will read 00 Revision C2 cards will read 01 Manual 104-QUAD-8...
311 04 o 312 01 Channel 1 data (24-bit) and flags (8-bit), card interrupt status (8-bit) o 301 11 i 300 i 300 i 300 i 301 i 310 o 311 04 repeat above 7 commands while turning encoder Manual 104-QUAD-8...
Both single-ended and differential Encoders require a ground connection between the Encoder and the PC/104 board to eliminate the adverse effects of exceeding the common mode range. If your encoder does not have an index signal, the Index Positive Input pin needs to be grounded. Manual 104-QUAD-8...
Both single-ended and differential Encoders require a ground connection between the Encoder and the PC/104 board to eliminate the adverse effects of exceeding the common mode range. If your encoder does not have an index signal, the Index Positive Input pin needs to be grounded. Manual 104-QUAD-8...
ISA bus address is set by jumpers (100-3E0h) Environmenta 0 C to +70 C (optional -40 C to +85 C) Operating Temperature: -50 C to +120 C Storage Temperature: Humidity: up to 95% RH, non-condensing Manual 104-QUAD-8...
If you experience any problems with this manual or just want to give us some feedback, please email us at: manuals@accesio.com. Please detail any errors you find and include your mailing address so that we can send you any manual updates. 10623 Roselle Street, San Diego CA 92121 Tel. (858)550-9559 FAX (858)550-7322 www.accesio.com Manual 104-QUAD-8...