Precautions

Please read this instruction carefully before use.
Do not attempt to disassemble or modify the product
Keep the product away from the external shocks or vibrations.
Do not use the damaged or peeled cables.
Do not use the product outdoors.
Product specifications and features are subject to change without notice.

Warranty Information

Free warranty service
In case of the defect is found caused by the design or the production flaw while using the product properly, a manufacturer is responsible for the faulty product and the
free warranty service for 1 year from the date of purchasing.
Even in the warranty service period, malfunction or damage of products caused by the inevitable incident such as a natural disaster is not subject of the free warranty
service.
Warranty service at a cost
The product that free warranty service period is expired.
Malfunction of the product caused by a user's fault.
Malfunction of the product caused by incidents.
Malfunction of the product caused by a natural disaster such as earthquake, flood, lightning and etc.
In case of the warranty service at a cost, a customer should cover the transportation costs.
Examples of a user's fault
Fault in case of attempts to disassemble or modify the sCLK-EX.
Fault in case of not following the operating instructions correctly.
Please read this operating instruction and FAQ section on our website carefully before asking for the warranty service.

Supplied contents

A sCLK-EX : The name is changed according to the option and frequency.
A sCLK-EX DC power cable
RF cable and Clock connect PCB : The standard sCLK-EX supplies a RF cable
and a Clock connect PCB, and will be added extra according to the option.
A U.FL – BNC cable : Supplied when ordering 50Ω Master Clock Option.
A MCX – BNC cable : Supplied when ordering 75Ω Master Clock Option.
A SATA power PCB

Specification

Internal reference clock
Custom designed ultra low phase noise oscillation circuit
Isolated differential clock signal distribution
Clock output
Isolated clock output : U.FL connector x 4
Supply matching board for connecting target board
Single clock frequency for interface system
sCLK-EX12 : 12MHz
sCLK-EX25 : 25MHz
sCLK-EX48 : 48MHz
sCLK-EX22/24 : 22.5792MHz / 24.576MHz selectable by SEL0 input
sCLK-EX45/29 : 45.1584MHz / 49.152MHz selectable by SEL0 input
Optional other frequency available
Dual independent clock frequency for digital audio system
sCLK-EX1412 : 14.318MHz, 12MHz
sCLK-EX1448 : 14.318MHz, 48MHz
sCLK-EX1425 : 14.318MHz, 25MHz
Optional other frequency available or selectable by SEL0, 1 input
Triple independent clock frequency for mother board & interface
sCLK-EX142512 : 14.318MHz, 25MHz, 12MHz
sCLK-EX142548 : 14.318MHz, 25MHz, 48MHz
Optional other frequency available or selectable by SEL0, 1 input
Quad independent clock frequency for mother board & interface
sCLK-EX14252612 : 14.318MHz, 25MHz, 26MHz, 12MHz
sCLK-EX14252648 : 14.318MHz, 25MHz, 26MHz, 48MHz
Optional other frequency available or selectable by SEL0, 1 input
Rev 1.5
A 3.5" bay bracket
A operating instruction
Ultimate High Performance Audio
Clock control input
Isolated control input connector x 2
Non isolated control input x 7
External master clock input : Optional
Input frequency : 10MHz (Optional other frequency available)
Isolated 50Ω external clock input : U.FL connector x 1
Isolated 75Ω external clock input : MCX connector x 1
Differential clock signal input & internal distribution
Power input
Input Voltage : 9Vdc ~ 12Vdc (optional 6.5Vdc ~ 8.5Vdc)
Operating current : 1A >
Power output
All output use ultra low noise regulator circuit
5V, 0.5A x 1
3.3V, 0.5A x 1
Power regulator circuit
Custom designed ultra low noise regulator circuit x 3
Standard ultra low noise regulator circuit x 1
Active noise canceller circuit
Components
Audio grade film capacitors
Audio grade tantalum capacitors
Operating environment
Operating temperature range: +10 ~ +30
o
Storage temperature : 0 ~ +40
C
Operating & storage humidity : 10% ~ 90%
www.sotm-audio.com
o
C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the sCLK-EX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SOtM sCLK-EX

  • Page 1: Warranty Information

    A operating instruction   RF cable and Clock connect PCB : The standard sCLK-EX supplies a RF cable  and a Clock connect PCB, and will be added extra according to the option. A U.FL – BNC cable : Supplied when ordering 50Ω Master Clock Option.
  • Page 2 : selectable by SEL0 or SEL1 input Precautions On the back side of the sCLK-EX, each clock output frequency is labeling by the sticker. When connecting RF cable to other  boards, be careful not to misconnect the frequency.
  • Page 3 Install the sCLK-EX48 using the supplied 3.5”bay bracket to the inside of PC case. Connect the PC’s SATA power cable to the supplied SATA power PCB. And connect it to the sCLK-EX48 by the supplied sCLK-EX DC power cable.. By the supplied RF cable, connect the soldered clock connect PCB( ) on the tX-USBexp to the Clock output 1 on the sCLK-EX48.
  • Page 4 Install the sCLK-EX12 using the supplied 3.5”bay bracket to the inside of PC case. Connect the PC’s SATA power cable to the supplied SATA power PCB. And connect it to the sCLK-EX12 by the supplied sCLK-EX DC power cable. By the supplied RF cable, connect the RF connector on tX-USBhubIN to the Clock output 1 on the sCLK-EX12.
  • Page 5 Install the sCLK-EX142548 using the supplied 3.5”bay bracket to the inside of PC case. Connect the PC’s SATA power cable to the supplied SATA power PCB. And connect it to the sCLK-EX142548 by the supplied sCLK-EX DC power cable. By the supplied RF cable, connect...
  • Page 6 VIII. If you commission SOtM or the seller do the upgrade on your main board, the labor cost and a round trip shipping cost should be requried. If any damage is occurred for the requested main board while processing the upgrade, the repair cost would be charged to SOtM, the seller and the client who requested this upgrade equally, and the repair cost is calculated depreciation on the requested main board.
  • Page 7: Installation Guide

    A U.FL – BNC cable is for 50Ω impedance, a MCX – BNC cable is for 75Ω impedance. Refer to the image below and connect the correct cable according to the correct impedance of the external master clock input to the sCLK-EX and fasten the BNC connector bracket to the PC case.

Table of Contents