Notes on the Installation, Initial Start-up, Operation
Radio Receiver FSE 514
BE-514_I-V1-3-FCC.doc.doc [ Word 2000 ] MB
HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY
Information and specifications subject to change without notice.
HBC

– Radio Control

R
a
d
i
o
R
e
R
a
d
i
o
R
e
c
e
i
v
e
r
F
S
c
e
i
v
e
r
F
S
Page 1 / 18
E
5
1
4
E
5
1
4
Radio System
30-04-2003

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FSE 514 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HBC FSE 514

  • Page 1: Radio Control

    Notes on the Installation, Initial Start-up, Operation Radio Receiver FSE 514 BE-514_I-V1-3-FCC.doc.doc [ Word 2000 ] MB Page 1 / 18 – Radio Control Radio System HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY Information and specifications subject to change without notice. 30-04-2003...
  • Page 2 Tel. +49 ( 0 ) 79 51 – 3 93 - 0 Fax +49 ( 0 ) 79 51 – 3 93 – 50 E-mail: info@radiomatic.com http://www.hbc-radiomatic.com HBC radiomatic GmbH is not liable for any misprints or errors ! – All rights reserved. ™ radiomatic is a registered German trademark. ©...
  • Page 3: Table Of Contents

    Safety Instructions for Installation and Operation ... 8 2.4 FCC-Rules ................... 9 Installation and Mains Connection ........10 Proper Installation of the FSE 514 Radio Receiver ....11 Radio Status Panel ..............12 Automatic HOLD Function Settings (Eltako) ....13 Fault Correction ...............
  • Page 4: Description

    The FSE 514 radio receiver is designed for the wireless reception of command instructions for controlling light-weight industrial cranes and small hoists. The FSE 514 radio receiver can receive and process up to 14 control commands. A non-interchangeable system address ensures the functional safety of the radio control system when operating cranes or machines, This feature is particularly important when several cranes or machines are in use, for example in halls and shops.
  • Page 5: Unpacking And Examining The Consignment

    ("Installation, Commissioning and Operating Instructions") To ensure that the radio control system arrives intact, HBC-radiomatic GmbH packs its systems in reusable packaging material. We recommend storing all packaging materials in a safe place in case of later use.
  • Page 6: Safety Instructions

    Pay attention to the comments and instructions given. Ignoring the information provided may permanently impair the reliability and operability of the equipment. Radio System HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY 30-04-2003 Information and specifications subject to change without notice.
  • Page 7: General Safety Instructions

    Defects must be repaired and objects of interference must be removed immediately ! A defective radio receiver may only be repaired by qualified and competent personnel. Use only original HBC spare parts. The use of any other spares will render the technical inspectorate approval invalid as well as substantially impede operative safety.
  • Page 8: Safety Instructions For Installation And Operation

    Never leave an activated transmitter unattended. The operator undertakes to follow and comply with the authoritative regulations for worker safety and accident prevention. Radio System HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY 30-04-2003 Information and specifications subject to change without notice.
  • Page 9: Fcc-Rules

    GmbH may void the FCC authorization to operate this equipment. RF EXPOSURE NOTICE: The radiated output power of the FSE 514 is far below the FCC radio frequency exposure limits. Nevertheless, the FSE 514 shall be used in such a manner that the potential for human contact during normal operation is minimized.
  • Page 10: Installation And Mains Connection

    ! The radio receiver FSE 514 is to be mounted using the rubber vibration dampers (included). The rubber vibration dampers are to be screwed to the mounting loops on the upper and lower edge of the receiver ℑ.
  • Page 11: Proper Installation Of The Fse 514 Radio Receiver

    Notes on the Installation, Initial Start-up, Operation Radio Receiver FSE 514 BE-514_I-V1-3-FCC.doc.doc [ Word 2000 ] MB Page 11 / 18 Proper Installation of the FSE 514 Radio Receiver Radio System HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY Information and specifications subject to change without notice.
  • Page 12: Radio Status Panel

    It is not until one or several drive commands (e.g. turn, trolley traveling, lifting gear or crane traveling) are input that the "SI 2" LED may be illuminated ! Radio System HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY 30-04-2003 Information and specifications subject to change without notice.
  • Page 13: Automatic Hold Function Settings (Eltako)

    The automatic HOLD function is activated (latched) when switches S2 und S3 are set to position II. The automatic HOLD function is deactivated (unlatched) when switches S2 und S3 are set to position I. Radio System HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY Information and specifications subject to change without notice. 30-04-2003...
  • Page 14: Fault Correction

    − The connection between securely fastened. crane / machine and − If necessary, call a receiver is faulty. service engineer or technician. Radio System HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY 30-04-2003 Information and specifications subject to change without notice.
  • Page 15: Maintenance

    HBC-radiomatic GmbH – Customer Services / Repair Service – Tel.: +49 ( 0 ) 79 51 – 3 93 – 800 Radio System HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY Information and specifications subject to change without notice. 30-04-2003...
  • Page 16: Technical Data

    Number of channels Channel separation 250 kHz Type of modulation 115KF1D RF sensitivity better than –95dBm @ BER=10 92,9dBµV/m RF power RF antenna internal Radio System HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY 30-04-2003 Information and specifications subject to change without notice.
  • Page 17: Dimensions Of The Fse 514 Radio Receiver

    Notes on the Installation, Initial Start-up, Operation Radio Receiver FSE 514 BE-514_I-V1-3-FCC.doc.doc [ Word 2000 ] MB Page 17 / 18 Dimensions of the FSE 514 Radio Receiver Radio System HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY Information and specifications subject to change without notice.
  • Page 18: Certificates And Approvals

    Notes on the Installation, Initial Start-up, Operation Radio Receiver FSE 514 Page 18 / 18 BE-514_I-V1-3-FCC.doc.doc [ Word 2000 ] MB Certificates and Approvals Radio System HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY 30-04-2003 Information and specifications subject to change without notice.