Hayward ProGrid DE2420 Owner's Manual page 8

Progrid series vertical grid d.e. filter
Hide thumbs Also See for ProGrid DE2420:
Table of Contents

Advertisement

WARNING
This product should be installed and serviced only
by a qualified professional.
BODY AND CLAMP RE-ASSEMBLY
1.
Place the metal reinforced seal on the lower filter body (Fig 4).
Place the upper filter body on the Hayward DEX2422Z2 metal
reinforced seal and lower filter body in a position which allows
all operation and safety labels to be clearly visible and the upper
body to be centered on the lower filter body. Press down firmly
and evenly to set the upper filter body. (Fig 7)
2.
Replace the filter clamp around the upper and lower filter
bodies. Hold the clamp ends to position the clamp on the filter
bodies with the clamp ends adjacent to the safety and operation
labels on the filter bodies. (Fig 7)
DO NOT HIT OR STRIKE CLAMP WITH HAMMER OR
METAL TOOLS.
3.
Insert clamp bolt through the clamp ends and thread the clamp
nut onto clamp bolt with rounded end of the nut (Fig 8) towards
the ends of the clamp.
4.
Never rely on hand tightening of clamp nut to clamp bolt.
Using a ¾" socket on a torque wrench, torque clamp nut to
clamp bolt to 150 inch-lbs. (Fig 9).
5.
Follow Operation Instructions for "Starting the Pump and Filter
System" (Page 5).
VACUUMING
Vacuuming can be performed directly into the filter whenever
needed. Backwash filter after vacuuming, if required.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Clamp Bolt
Clamp Nut
Figure 8
Clamp Bolt
Clamp Nut
Figure 9
Figure 7
Tighten clamp
bolt and nut
using a
torque
wrench to 150
inch-lbs.
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents