METHOD OF CHECK
DC excessive current detection and in case of irregular work of compressor
Flow Chart
check the damage of piping, excess gas
check the resistance of PCB(Power module) [see fig.5]
normal
check the voltage (230V) between
1 and 2 in terminal of TAG
normal
check the voltage of TAG PCB(main)
normal
accident of compressor
NO
accident of PCB(Power module)
YES
NO
YES
[see fig.6]
NO
take off the connectors
YES
the resistance of TAG PCB(main)
TROUBLESHOOTING GUIDE
check the power supply wiring
&
23
NO
normal
YES
accident of PCB(Power module)
– 16 –
24
[see fig.7]
accident of TAG PCB(main)