Item
LED Control
Buzzer Control
RS-232 Connection
Tamper control
Cable Wiring
controller.
Connect the white line of the product to the Wiegand D1 input port of the
controller.
Enables you to turn on or off the LED indicators.
To control green indicator, connect the yellow line to the controller's
output (relay). Connect the Gray to control the orange indicator, connect
the white with red stripes to control the red indicator. See
Enables you to turn on or off the buzzer.
To control the buzzer, connect the blue line to the controller's output
(relay). See
1.5 Buzzer Control
Connect to the COM port of the PC. (Connect pin 2 of the DB-9 connector
to the purple line; connect the black of the device (RS-232 GND) to pin 5
of the DB-9 connector)
Connect the COM port (Pink line) of the product's tamper switch to GND;
connect the NC port (Light yellow) of the tamper switch to the input port
of the controller.