Download Print this page

Specifications; Installation Instructions - Netway spectrum NetWaySP8A Installation Manual

Media converters/repeaters

Advertisement

Altronix NetWaySP8A, NetWaySP16A media converter/repeaters convert a 10/100/1000 Mbps to Fiber (1000Base-X/SX/LX).
Agency Listings:
• CE approved.
Input:
NetWaySP8A:
• 115VAC, 60Hz, 0.5A or
230VAC, 50/60Hz, 0.3A.
NetWaySP16A:
• 115VAC, 60Hz, 1.2A or
230VAC, 50/60Hz, 0.75A.
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction. NetWaySP8A/NetWaySP16A is not
intended to be connected to outside plant leads. These products are for indoor use only and must be installed within the protected premises.
1. Attach mounting brackets to the unit for rack or wall mount installation (Fig. 3 or 4, pg. 4). Affix rubber pads to the unit
for shelf installation (Fig. 5, pg. 4).
2. Secure the unit in a rack or on a wall, or place unit on a shelf as desired.
Note: The following factors should be taken into consideration when installing these rack mount units:
a. The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC).
b. Take care to ensure that there is sufficient air flow around the unit and that obstructions do not impede it.
c. When mounting units in a rack, take care to avoid uneven loading which can cause a hazardous condition.
3. Plug the grounded AC line cord (included) into the IEC 320 connector of the unit (Fig. 1d, pg. 2). Plug unit into a reliable earth grounded socket.
When using multiple units, the sum of the individual name plate ratings should not exceed the supply circuit rating.
Do not connect to a receptacle controlled by a switch.
4. Connect structured cable from port(s) marked [1-8 or 1-16] on NetWaySP8A/16A to the corresponding input(s) of an UL Listed ethernet switch (Fig. 1c, pg. 2, Fig. 2, pg. 3).
5. Connect fiber optic cable to a fiber SFP module. Connect the module to the port(s) marked [SFP1-SFP8, SFP1-SFP16] on the NetWaySP8A/16A. Connect the other end
of fiber cable to an SFP module of a remote device. SFP LED will illuminate indicating data connection (Fig. 1a, pg. 2, Fig. 2, pg. 3).
Fig. 1
Front Panel
1c
Rear Panel
5
1
2
6
3
7
8
4
9
10
11
12
www.altronix.com
Fiber Ports:
NetWaySP8A:
• Eight (8) 1Gb SFP ports.
NetWaySP16A:
• Sixteen (16) 1Gb SFP ports.
Ethernet:
NetWaySP8A:
• Eight (8) 10/100/1000 Mbps.
NetWaySP16A:
• Sixteen (16) 10/100/1000 Mbps.

Installation Instructions:

1a
1b
SFP 1
SFP 2
SFP 3
SFP 4
SFP 5
SFP 9
SFP 10
SFP 11
SFP 12
SFP 13
5
6
7
8
13
14
15
16
Overview:

Specifications:

1a 1Gb SFP port.
1b LED indicates fiber link.
1c RJ45 connects to switch
1d IEC 320 Connector: 115/230VAC (grounded line cord included).
SFP 6
SFP 7
SFP 8
SFP 14
SFP 15
SFP 16
1d
- 2 -
LED Indicators:
• Ethernet (RJ45): Indicates speed - 100 (green) /
1000 (yellow)
• Link SFP: Indicates SFP connection.
Environmental:
• Refer to Environmental Conditions on page 3.
Dimensions (W x L x H approx.):
1.625" x 19.125" x 8.5" (41.3mm x 486mm x 216mm).
NetWaySP8A / NetWaySP16A

Advertisement

loading

This manual is also suitable for:

Netwaysp16a